functioning at their best if they are regularly maintained. This particularly applies to our smoke and fire protection products, which have room-sealing effects designed to save lives. This is where we come [...] help the owner and the users to ensure that the facilities for structural, technical and defensive fire protection, as well as any service installation systems, are properly maintained and operational at [...] KB) Safety Data Sheet 450.093 + 450.163 (297 KB) Operating Instructions Hinge alignment tool 499.651 (2 MB)
Text - Referenzlandingpages - EN The concept is supported by the Jansen Janisol2 EI30 and Janisol C4 EI90 products. With Janisol2, multifunctional transparent internal attachments and partition walls with [...] double-leaf glass doors Janisol C4. The thermally insulated Janisol C4 fire door adds further fire protection with an innovative ceramic filling in sophisticated steel profiles up to a fire resistance class of [...] the fire protection requirements of a heavily frequented office building. On each floor except for the basement, this reception area opens up to the floors by means of fixed glazing with Janisol2 EI30
Vorlage - Nur Text - Referenzlandingpages - EN Thanks to this wide range of construction options, Janisol Arte 2.0 was ideally suited to the project with its many different windows and opening types. For five [...] patio doors with a round arch. Fixed fire-resistant glazing proved to be challenging in terms of production technology, and with a folding wall made from the Janisol steel profile system, the challenge [...] sashes without any noticeable difference in the width of the elevation: this is only possible with Janisol Arte 2.0 .
class E30/EW30/E60/EW60 fire doors and fixed lights up to class E90 can be fitted. The appearance of the Jansen Economy doors is identical with that of the Janisol2 and Janisol C4 fire safety systems. The [...] possible Also possible with fire protection and smoke protection combined or only with smoke protection ( Smoke control doors Jansen Economy 60 RS ). Also possible without fire protection, see link for details [...] details ( Jansen Economy 60 door ). Test certificates Fire resistance class E30/EW30/E60/EW60 Smoke control in accordance with DIN 18095 Smoke control tested in accordance with EN 1634-3 Durability (C5)
very narrow face widths. The appearance is identical to that of the other fire protection systems Economy 60, Janisol2 and Janisol C4. Materials / surface Uncoated or strip-galvanised steel, suitable for [...] Fire doors and fire-resistant partitions of class E30/EW30/E60/EW60 can be easily assembled using the tried-and-tested Economy profiles. It is even possible to achieve fire resistance classes up to E120 [...] possible Also possible with fire protection and smoke protection combined or only with smoke protection ( Smoke control doors Jansen Economy 50 RS ). Also possible without fire protection ( Jansen Economy
including heavy-duty T connectors Motorised Janisol HI bottom-hung vents Two-leaf, outward-opening VISS side-hung door Automatic VISS sliding door 5 x 4 m Janisol HI doors Commitment to sustainability Lo [...] and optimise internal lighting conditions (SageGlass from Saint Gobain) Downloads Technology Center (2 MB)
doors. More about the Janisol Arte 2.0 Plus door VISS Fire Facade EI30 RC2/3 Further development: VISS facade system combines fire and burglary protection For the combination of fire protection and burglary [...] the VISS Fire facade EI30 RC2/3. This development aims to offer multifunctionality by providing both effective fire protection and high burglary protection. More about VISS Fire Facade EI30 RC2/3 Further [...] Customized Solutions Janisol Arte 2.0 Plus Design and safety Extremely narrow face widths and outstanding performance values characterize the thermally broken steel system Janisol Arte 2.0 Plus, which has
from the Janisol door system (60) and insulators from the Janisol Primo system, the new Jansen Janisol 70 system combines proven quality and the option of using triple insulated glass. Jansen Janisol 70 can [...] up to class C4/B4 (1600 Pa) Heat transfer coefficient U f > 1.1 W/m 2 K Continuous function test class 8 (1,000,000 cycles) Class 2 operators Shear bond according to EN 14024 Escape door compliant with
The slender profile face widths of the Janisol windows made of steel or stainless steel provide space for creativity and lend the building a quite special character. Whether it is sash bar variants, arched [...] arched windows or large-element glazing: the Janisol window system is particularly suitable for use in new buildings as well as for the refurbishment of existing buildings. Materials/surface finishes Uncoated [...] class C4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal transmittance Uw > 1.5 W/m 2 K Mechanical strength class 4 Operating forces class 1 Impact resistance class 5 Load-bearing capacity
environmentally compatible sustainable building. The assembly and manufacture of Janisol Primo and combination with Janisol systems are simplified by the use of identical profile cross sections. Materials [...] class C4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal transmittance Uw > 1.0 W/m2K Shear bonding in accordance with EN 14024 Burglar resistance in accordance with EN 1627 up to RC (WK)
against heavy rain up to class 6A Air permeability up to class 4 Resistance to wind load up to class C2/B2 Airborne sound insulation up to Rw 39 dB Shear bonding in accordance with EN 14024 [...] The Janisol lift-and-slide door programme re-defines the living room. The proven system, which has been re-developed for large openings, allows the indoors and the outdoors to merge and in this way creates [...] disable access threshold and, on the other hand, also guarantees optimal thermal insulation. The Janisol lift-and slide doors are CE-compliant and have been tested at ift Rosenheim. Materials / surface
achieve windows with excellent thermal conductivity coefficients (Uw), e.g. 0.69 W/m2K for fixed lights and 0.8 W/m2K for opening elements. Thanks to high-tech thermal break spacer bars made of glass-fibre [...] insulation up to Rw 46 dB Heat transmission coefficient Uw > 0.69 W/m2K for fixed glazing Heat transmission coefficient Uw > 0.8 W/m2K for windows Shear bonding in accordance with EN 14024 Tests in accordance [...] Janisol HI windows combine aesthetics with refined technology. Slender frame profiles enhance the architectural styling while the innovative technology ensures the best possible thermal separation. With
The Janisol HI door system fulfils maximum insulation requirements and, with respect to safety/security and durability, is also suitable for extreme service conditions – such as those in very busy public [...] glazing, it is easy to achieve doors with excellent thermal conductivity coefficients of U d 1.0 W/m2K. Thanks to high-tech thermal break spacer bars made of glass-fibre reinforced plastic, the new door [...] excellent structural values and achieves top values in system tests (air/water/wind/mechanics). With Janisol HI, Jansen sets new benchmarks in terms of contemporary architecture combined with excellent thermal
The Janisol folding partition is based on the thermally insulated Janisol system and is flexible in use. It can be used as a room divider or for the exterior. The proven system – newly developed for flexible [...] ng glass doors 2 to 6 leaves Inward- and outward-opening Any leaf arrangement Equipment Fittings up to 200 kg Weight of leaf up to 100 kg Leaf widths up to 1'000 mm Leaf heights up to 2'900 mm Special
also increasingly observed in the private sector. Burglar resistance with RC2 classification is often sufficient here, as RC2 offers protection for up to three minutes. Only a few additional parts are required [...] centres and the like. Stainless steel adds a graceful look and reduces maintenance to a minimum. Janisol stainless steel is therefore the right choice for shopping malls, railway stations, banks and hotels [...] required, which also remain invisible. The elegant appearance of the Janisol door remains eye-catching. Materials/surface finishes Uncoated or strip-galvanised steel, suitable for powder coating or st
result is fire protection doors that optimally combine strength with the highest fire protection characteristics. Thanks to the innovative fire protection infill, it is possible to achieve fire resistance [...] Central glazed panel Dry glazing and glazing with putty Door heights up to 2.50 m with single-latch lock Test certificates Fire resistance classes EI60 and EI90 tested in accordance with EN 1634-1 and DIN
usual way, as with the Janisol and Janisol Arte 2.0 steel profiles – this ensures a high level of process reliability. Benefits Modern opening type Compatible with Janisol Arte 2.0 Concealed fitting Free [...] Slim tilt and turn windows made from steel profiles With Janisol Arte 66, Jansen is expanding its range of systems to include an attractive variation. The basic depth of 66 mm enables the use of stronger [...] Watertightness up to class 9A (600 Pa) Sound reduction up to 47 dB Thermal transmittance of Uf from 1.9 W/m2K Air permeability class 4 (600 Pa) Load-bearing capacity of safety devices met Mechanical strength class
Janisol Arte 2.0 door Extremely slim face widths and outstanding performance values are the hallmarks of the Janisol Arte 2.0 thermally separated steel system, which has previously been used to manufacture [...] system and the Jansen Art'System window system. Janisol Arte 2.0 door Doors made of steel, stainless steel and Corten steel with narrow face widths Janisol Arte 2.0 window Slender steel window system for matching [...] Design and functionality Dimensions Range of applications Janisol Arte family Materials References Performance values Contact Janisol Arte 2.0 Webinar Register now to receive the recording of the webinar:
steel window system for matching the existing style in refurbishments The second generation of the Janisol Arte window system now offers profiles made from stainless steel and Corten steel as well as a wide [...] Watertightness up to class 9A (600 Pa) Sound reduction up to 45 dB Thermal transmittance of Uf from 1.9 W/m2K Air permeability class 4 (600 Pa) Load-bearing capacity of safety devices met Mechanical strength class [...] safety barrier loading DIN 18008-4 met Burglar resistance tested in accordance with EN 1627 up to RC2
profile system Janisol Arte, extremely large sliding doors with slim face widths and high stability can be prepared. Originally developed by Jansen for the reconstruction of historic windows, Janisol Arte now [...] to 3000 × 2500 mm (W×H) Max. weight 150 kg/leaf Insulating glass from 20 to 34 mm UW value of 1.5 W/m2K Welded steel profile half shells in combination with glass-fibre reinforced high-performance plastics
various lock versions, a wide range of materials – namely steel, stainless steel and Corten steel). Janisol Arte 2.0 doors are therefore the right choice for renovations to existing buildings and modern structures [...] C5/B5 (2000 Pa) Airborne sound insulation up to Rw 45 db Heat transmission coefficient UD > 1.9 W/m2K Shear coupling in accordance with EN 14024 Mechanical strength in accordance with EN 13115 up to Class
sliding fire door system, with its particularly slender frame profiles, appeals in terms of function as well as aesthetics. The door profile system has been successfully tested under EN fire resistance [...] Test certificates Tested in accordance with EN 1634-1 Fire resistance class EI30 Emergency exit door in accordance with EN 1125 / EN 179 Swiss fire protection approvals [...] options are available due to the large selection of drive units and types of glass. The EI30 sliding fire door is mainly used in barrier-free buildings with increased safety requirements, such as shopping
depth 70 mm. In this way transparent Janisol C4 EI60 fire-resistant partitions - in the extreme case even EI90 fire-resistant partitions- can be combined with Janisol2 EI30 without problems. Material / surface [...] of various fire protection requirements. So that technically demanding combinations also meet aesthetic requirements, individual door profiles in the proven fire protection system Janisol2 EI30 have been [...] Test certificates Tested in accordance with EN 1634-1 Fire resistance class EI30/EI60/EI90 Emergency exit door in accordance with EN 179 / 1125 Swiss fire protection applications
The Janisol2fire protection system fulfils the requirements for safety and design freedom in buildings like no other system. The material properties of steel make it possible to create very strong and [...] doors that also meet all of the requirements set out in EN 16034. The highly heat-insulating Janisol2fire protection doors allow for complete automation and people are thus able to walk through the door [...] up to 2.5 m with single-latch lock Door height up to 3.0 m with single-latch lock and bi-metal lug or single-latch lock with top retracting bolt Also available as anti-finger-trap door Janisol2 EI30 Test
opening size, double door: 3000 × 3000 mm Also available as fire doors and fire-resistant partitions – Janisol2 EI30 Test certificates Fire resistance EI30 to EN 1634-1 and DIN 4102-5 Smoke control in [...] The Janisol2 EI30 anti-finger-trap fire doors reduce the potential risk of injury at the secondary closing edge to a minimum thanks to rounded half shells. They are therefore particularly suitable for [...] airports. The anti-finger-trap door looks identical to other Jansen anti-finger-trap doors without fire protection rating. In addition, the door can be fitted with many types of glass and is easy and efficient
Full fire safety range The Janisol 1 system for windows and fixed glazing as well as the systems for doors and fixed glazing round off the fire safety product range. The system meets fire resistance class [...] installation depth or 60 mm (window frame) or 64 mm (window casement) and has the same face as the Janisol window. It also impresses thanks to its simple and efficient processing. Field Renovation and new [...] mm Test certificates System tests in accordance with the EN 14351-1 and EN 16034 product standards Fire resistance E45/EW45 Wind load resistance C4 (1600 Pa) Tightness against heavy rain of up to class
AG, Customer Information Centre, Oberriet 2 ½ days Day 1: 08:30 – 16:30 Day 2: 08:30 – 16:45 Day 3: 08:30 – 14:00 Attendance fee CHF 300.- per person (including 2 overnight stays) Please note The number [...] at new Jansen customers and newcomers to the industry. The following topics are covered during the 2 ½ days. Content Wind, water, air tests See profiles being manufactured Instruction in how to use the [...] Jansen facade systems - Jansen thermally insulated systems - Jansen non-insulated systems - Jansen fire protection systems Jointing techniques in unit construction Sawing, welding, grinding of steel and
is also being included as part of the current revision of the standard for internal doors (EN 14351-2). Therefore, in future, these requirements will also apply for escape doors in indoor areas. Implementation [...] escape doors must implement certain measures. This applies for doors with as well as those without fire or smoke protection properties. The following steps must be carried out to fulfil requirements within
second glance. The large windows were faithfully reconstructed using the thermally separated Janisol Arte 2.0 steel profile system and structurally reinforced. OPB Obermeyer Planen + Beraten , Berlin/DE
interior of the building. Intricate refurbishment profiles With a large variety of opening types, Janisol Arte 2.0 is just as ideal for the refurbishment of historic windows as it is for windows in trendy new
effective fire protection with maximum transparency: a storey-high Jansen VISS Fire TVS EI60 mullion-transom façade made of steel provides 60 minutes of fire resistance around the atrium. Janisol2 EI30 and [...] and Janisol C4 EI60 steel fire doors are integrated into this. Numerous Schüco Alumnium systems, such as the Schüco FWS 50.SI mullion/transom façade, were also fitted. With the freely accessible roof terrace
new atrium. The mosaic was laminated onto fire-resistant glazing and the ready-to-install panes were mounted in a mullion and transom facade made of the VISS Fire steel profile system. On the ground floor [...] Fire-proofing the past In the course of a general renovation with partial new construction, the "Haus der Wirtschaft" (House of Business) has been created on Nuremberg's main market square. A large-format [...] floor, a double-leaf revolving door made of the Jansiol 2 steel profile system and integrated into the glass mosaic connects the historic hall building with the new atrium. Behles und Jochimsen , Berlin/DE
cladding made from heat-insulating trapezoidal sheets, a new window layout made from the narrow Janisol Arte 2.0 steel profiles, and no shortage of passion and commitment from the operators, the dream property
archives of the fortress, the existing composite windows were replaced by mullioned windows made of Janisol Arte 2.0 . In order to preserve the appearance of the building as best as possible, the panes were sealed [...] make 20 mullioned windows with ventilation sashes. "Thanks to the excellent profile properties of Janisol Arte and our technical know-how for special constructions, the original windows could be recreated
Reconstructed windows - Janisol Arte 2.0 The building features a variety of window formats, including large sectioned windows that extend across the entire height of the hall. Glaskunst Buhlig produced
behaviour in a fire. The fire resistance class indicates how long a building component or fire protection barrier reliably preventing the spread of a fire. Building material classes and fire resistance classes [...] countries. Material classes and fire resistance classes Fire protection in buildings is aimed at minimising the effects and preventing the spread of a fire. In order to assess the fire load, the materials are [...] Fire protection Protecting human lives and material assets from destructive flames Fire is fascinating – as long as we can keep it under control. However, if an uncontrolled fire breaks out, all we can
Fire Station, Multi-Purpose Space and Emergency Housing The oversized windows were each designed with a rounded corner. These are based on Janisol Arte 2.0 window steel profiles, which were each manufactured
with staggered opening ventilation sashes. The Janisol steel profile system in the form of the Janisol HI window elements used as well as Janisol2 EI30 fire protection sliding doors cover the requirements [...] with staggered ventilation sashes for opening. With this in mind, the Janisol steel profile system – seen here in the form of the Janisol HI window elements – meets the special requirements of the building [...] envelope of a research building. Boltshauser Architekten , Zurich/CH Aepli Metallbau AG , Gossau/CH Janisol C4 fire dampers CH-Zurich
facade are covered, among other things, by a mullion-transom facade made of VISS Fire Facade EI30 . Janisol2 EI 30 fire doors and Jansen-Economy 50 profiles are the ideal complement. Nickl & Partner A
the requirements with regard to fire and smoke protection properties. It must always be used in combination with EN 14351-1 for external pedestrian doorsets or EN 14351-2 for internal pedestrian doorsets [...] standard for this (EN 14351-2) has not yet been harmonized. What does this have to do with me as a metal fabricator? The standard also includes requirements for manufacturers of fire protection barriers. Fulfilment [...] EN 16034? Can we help you in any way? We would be pleased to hear from you. Download Flyer EN 16034 Fire protection training Contact
fabricators who have not yet completed any fire protection training for Jansen fire protection systems will be trained over 2 days. The first 1.5 are used to explain the fire protection systems, standards and key [...] updating their licence, Swiss metal fabricators who have already successfully completed the Jansen fire protection licence training only need to pass training for EN 16034 and the associated product marking [...] results of the tests carried out in line with EN 16034 and forms the basis for the European approval for fire and smoke protection barriers. In the course of the approval process, the ATD replaces the Type Testing
components measuring up to twelve square metres can be produced without any problems in terms of heat and fire protection. Solar control Rooms that let in a large amount of daylight can be blighted by glare and [...] rooms must therefore be carefully balanced and planned. Reliable heat input through insolation DIN 4108-2 describes a simplified method for determining the permissible solar transmittance value (S perm). The [...] These may be affected by the use of solar control glass or sun-shading louvres. EN 13363 Parts 1 and 2 describe methods for calculating the values. Structural solar protection on buildings Special insulation
33065 and VKF 33069) with combined requriements regarding fire protection as well as break in/break out resistance and is based on the Janisol2fire protection system for doors. Special features: leaf size [...] × 3190 mm (W × H) Leaf weight up to 180 kg Burglar resistance RC2 Zero threshold possible, including for RC2 → Discover the Janisol Arte 2.0 door now Do you have a suitable project? Contact us now! Glass [...] water tightness - for external use → Discover Janisol Arte 66 windows now Do you have a suitable project? Contact us now! Oversized designer door - Janisol Arte 2.0 Plus The Plus solutions from Jansen represent
RISCO. Various Jansen systems were used in this project, with Janisol and Janisol Arte2.0 predominating, but the fire-resistant system Janisol2 EI30 came also into use. The object was the winner in the category
building and fire protection in agreement Heatherwick Studios put forward the idea of having Frener & Reifer construct their facade. The experienced metal construction company used the Janisol Arte and Janiso [...] proportion of glass to be used with optimal thermal insulation and at the same time adhere to the latest fire protection regulations. They were combined with the fully insulated VISS glazing bar system. Heatherwick