efficiency. To achieve this combination, Wüst Metallbau AG used steel profiles from Janisol Arte 2.0 . They allowed the developers to achieve the desired rough industrial look, whilst at the same time [...] up to 2.7 W/m2K and triple insulating glass panes with a total thickness of 40 millimetres (u-value 0.6 W/m2K) were used on all 38 windows. Architekten Kaspar Partner , Zurich/CH Wüst Metallbau AG , Alt
8 x 1.0 10 x 1.3 12 x 1.3 14 x 2.0 16 x 2.0 17 x 2.0 18 x 2.0 20 x 2.0 26 x 3.0 32 x 3.0 Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/4 bar Kl 5/4 bar Kl 4/8 bar Kl 5/6 bar Kl 4/8 bar Kl 5/6 bar Kl [...] Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar
mm 6.9 mm 186.2 mm 6 m 250 mm 8.6 mm 232.8 mm 6 m 315 mm 10.8 mm 293.4 mm 6 m 400 mm 13.7 mm 372.6 mm 6 m [...] ratio 0,40 [-] Length variation 0,14 mm/mK Dimension dn Wall thickness en Internal diameter di Manufactured length 110 mm 3.8 mm 102.4 mm 6 m 125 mm 4.3 mm 116.4 mm 6 m 160 mm 5.5 mm 149.0 mm 6 m 200 mm [...] building developments Sewers Seepage pipes External diameter dn 110 to 400 mm Length Manufactured length 6 m Non-standard lengths on request Available with integrally formed push-fit connector Annular rigidity
mm 6 and 10 m 160 mm 6.2 mm 147.6 mm 6 and 10 m Serie 16 / SDR 33, SN 2 Dimension dn Wall thickness en Internal diameter di Manufactured length 200 mm 6.2 mm 187.6 mm 6 and 10 m 250 mm 7.7 mm 234.6 mm [...] mm 6 and 10 m 315 mm 9.7 mm 295.6 mm 6 and 10 m 355 mm 10.9 mm 333.2 mm 6 and 10 m 400 mm 12.3 mm 375.4 mm 6 and 10 m [...] Poisson's ratio 0,40 [-] Length variation coefficient 0,18 mm/mK Serie 12.5 / SDR 26, SN4 Dimension dn Wall thickness en Internal diameter di Manufactured length 110 mm 4.2 mm 101.6 mm 6 and 10 m 125 mm
mm PN 16 0.517 l 40 x 3.7 mm PN 16 0.802 l 40 x 4.1 mm PN 18 0.762 l 40 x 4.5 mm PN 20 0.725 l 50 x 4.6 mm PN 16 1.255 l 50 x 5.6 mm PN 20 1.135 l 50 x 6.9 mm PN 25 0.988 l 50 x 7.9 mm PN 30 0.881 l The
Coils in the conduit 16 x 63 mm 16 - 32 mm 16 - 32 mm 16 und 20 mm 16 x 2.0 20 x 2.0 26 x3.0 32 x 3.0 40 x 3.5 50 x 4.0 63 x 6.0 Kl 1-5 10 bar Kl 1-5 10 bar Kl 1-5 10 bar Kl 1-5 8 bar Kl 1-5 8 bar Kl 1-5
15876 SKZ-A141 Variants Dimensions Coils 8 to 20 mm 8 x 1.0 10 x 1.0 12 x 1.3 14 x 2.0 14.5 x 1.8 15 x 1.5 15 x 2.5 16 x 2.0 17 x 2.0 18 x 2.0 20 x 2.0 KI 4/10 bar KI 5/8 bar KI 4/10 bar KI 5/8 bar KI 4/5 10 [...] 10 bar KI 4/5 10 bar KI 4/5 10 bar KI 4/8 bar KI 5/6 bar KI 4/5 10 bar KI 4/5 10 bar KI 4/5 10 bar KI 4/5 10 bar KI 4/10 bar KI 5/8 bar
temperature -20° C … +40°C (DIN 8074) Production according to SIA 384/6, ÖWAV 207, VDI 4640, etc. DVS 2212-1, REACH Hydrostatic load class p0 Load capacity of lid 200 kg Lines looking downwards All circuit
corrugated pipe ~30 W/mK Minimum bending radius 0.45 m @ 20° C Pressure rating PN 7.4 Safety factor 1.25 Burst pressure 24.1 bar @ 20° C Buckling pressure 6 bar @ 20° C Volume per probe meter 4.54 l/m Special
(DIN 8074) Production according to SIA 384/6, ÖWAV rule sheet 207, VDI 4640, etc. DVS 2212-1, REACH Hydrostatic load class Standard: p1.5 (0.15 bar) Option: p5 (0.5 bar) / p10 (1 bar) Load capacity of lid
pre-assembled Smooth pipe 32 mm Minimum bending radius 0.45 m @ 20° C Pressure rating PN 7.4 Safety factor 1.25 Burst pressure 24.1 bar @ 20° C Buckling pressure 6 bar @ 20° C Volume per probe meter 1.9 l/m Special [...] durable product certified according to current standards and that meets the requirements of SIA 384/6, ÖWAV (Austrian Water and Waste Management Association) rule sheet 207 and VDI 4640. The heat loop base
requirements Thickness of infill elements, 6 to 70 mm Test certificates CE marking in accordance with EN 13830 Coefficient of thermal transmittance Uf > 0.95 W/m2K Tightness against heavy rain class RE1200
Length Filling volume per m heat loop JANSEN vertex Single-U 50 x 4.6 mm; PN 16 250 to 300 m 5.231 l/m JANSEN vertex Doppel-U 50 x 5.6 mm; PN 20 250 to 350 m 4.73 l/m JANSEN vertex Doppel-U 50 x 7.9 mm [...] per heat loop) Minimum bending radius for dimension 50 mm 1000 mm @ 20° C 1750 mm @ 10° C 2500 mm @ 0° C Pressure ratings PN10, PN16, PN20, PN25, PN30 Safety factor 1.25 Volume per tube meter 5.23 l/m 4
Fluid pipe, welded Sleeve pipe push-fitted with sliding sleeve Thermal conductivity of insulant λ = 0.03 W/mK of PUR foam Min. thickness of insulation 25 mm Fluid pipe dn Outer pipe dn Thickness of insulation [...] mm 200 mm 38.8 mm 125 mm 200 mm 31.3 mm 160 mm 250 mm 37.3 mm 200 mm 315 mm 47.8 mm 250 mm 355 mm 41.6 mm 315 mm 400 mm 30.2 mm
of infill elements, 6 to 70 mm Construction depths 50 to 280 mm Test certificates CE marking in accordance with product standard EN 13830 Coefficient of thermal transmittance Uf > 0.65 W/m2K Airborne sound
service temperature -20° C … +40°C (DIN 8074) Hydrostatic load class p0 Load capacity of lid A15 (1.5 t) Production according to SIA 384/6, ÖWAV Regelblatt 207, VDI 4640, etc. DVS 2212-1, REACH Robust und
requirements of SIA 384/6, ÖWAV rule sheet 207 and VDI 4640. JANSEN powerwave collect design tool External diameter 63 mm Wall thickness 2.9 mm (SDR 22) Minimum bending radius 0.45 m (at 20° C) Capacity
74 92 49 0 E-mail: datenschutz@ remove-this. dsb-moers.de Further information for the visitors of our website from the EU We process personal data according to the following legal grounds: Art. 6 section [...] the internet. Legal basis The legal basis for the use of web analytics is your consent as per Art. 6(1)(1)(a) of the GDPR. Recipient/categories of recipients The recipient of the data collected is the [...] agreement with Google Ireland Ltd. ( https://www.google.com/intl/de_US/help/terms_maps.html ) as per Art. 6(1)(b) of the GDPR in conjunction with a joint controller agreement as per Art. 26 of the GDPR, which
Kolaylaştırılmış imalat; profiller için yeni bileşenler
Janisol Arte 2.0 Janisol Arte 2.0 paslanmaz çelik Janisol Arte 2.0 Corten çelik
Planlama avantajları
• Sabit cam / kanat içe ve dışa doğru açılır [...] Fire EI60)
64 STEEL SYSTEMS PROFIL SISTEMLERI
Jansen AG
K
1
0
1
7
5
2
8
I
St
e
el
S
y
st
e
m
s
I
0
4
.2
0
1
9
I
D
e
ği
şt
ir
il
eb
il
ir
Türkiye İrtibat Bürosu [...]
Janisol HI 1.0 W/m2K Ud değerlerine
ulaşabilmektedir.
Optimum ısı yalıtımlı çelik pencereler
Yüksek yalıtımlı çelik kapılar ısı geçirgenliği
minimuma indirger
pencere için 0.8 W/m2K Uw değerlerine
ÜZ Mainfranken received the award for its "ÜZ – adding value to renewable energy" project. More than 6,350 system s are connected to the grid operated by the energy cooperative, which produces its electricity [...] the 63 mm diameter JANSEN powerwave corrugated pipe results in a larger heat-exchange pipe surface (0.22 m²/m), which allows considerably more energy to be absorbed from the ground. In parallel with this [...] designed to be smaller and hence more cost-effective. Other projects A design originally based on a 10.6 kW heat output heat pump and two conventional 32 mm diameter double-u heat loops each 125 m long was
supplier. If the zero-defect requirement is violated, Jansen AG may reject the goods. 6 Material and tools provided 6.1 Material made available to the Supplier remains the property of Jansen AG. It must [...] release. 16.5.4 The transfer of risk and ownership takes place at the time of commissioning. 16.6 Training 16.6.1 Training on the equipment is carried out at the Jansen AG site. For each training course, the [...] missing drawings, changes, additions or adjustments to drawings and other information about drawings. 2.6 If Jansen AG provides the Supplier with material for processing, the Supplier shall inspect it immediately