view out. Test certificates Q-Signet FFF Air permeability class 4 Tightness against heavy rain 9A Wind resistance up to wind load class C3 Sound insulation Rw 37 dB
building a sense of spaciousness. The strict security standards were met using the VISS Fire and Janisol C4 systems. Read more in the online magazine SCALE Ayala , Madrid/ES Inasus , Lalin/ES Proinller , Madrid/ES
Tightness against heavy rain up to class 8A (450 Pa) Air permeability up to class 4 Resistance to wind load up to class C3/B3 Operating forces class 1 Airborne sound insulation up to Rw 45 dB
appearance is identical to that of the other fire protection systems Economy 60, Janisol 2 and Janisol C4. Materials / surface Uncoated or strip-galvanised steel, suitable for powder coating or stove-enamelling [...] control in accordance with DIN 18095 Smoke control tested in accordance with EN 1634-3 Durability (C5) tested in accordance with EN 1191 Emergency exit door in accordance with EN 1125 / EN 179
14351-1 Tightness against heavy rain up to class 9A Air permeability up to class 4 (600 Pa) Resistance to wind load up to class C4 (1600 Pa) Airborne sound insulation up to Rw 45 db Coefficient of thermal t [...] (1'000'000) Mechanical strength in accordance with EN 1192 class 4 Prefabricated glazing suitable for safety barrier loading DIN 18008-4 met Emergency exit door in accordance with EN 1125 / EN 179 Burglar
control in accordance with DIN 18095 Smoke control tested in accordance with EN 1634-3 Durability (C5) tested in accordance with EN 1191 Emergency exit door in accordance with EN 1125 / EN 179
to class 4A Air permeability up to class 4 Resistance to wind load up to class C5 Sound insulation up to 44 dB Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance FB 4-6 S/NS [...] S/NS Emergency exit door in accordance with EN 1125 / EN 179 Mechanical strength class 4 Conditions for approval fulfilled Conditions for supporting safety devices fulfilled
class 4 Resistance to wind load up to class C5 Sound insulation up to Rw 45 dB Emergency exit door in accordance with EN 1125 / EN 179 Bullet resistance up to FB6/NS Mechanical strength class 4 Conditions
14351-1 Tightness against heavy rain up to class E900 Air permeability up to class 4 Resistance to wind load up to class C4/B4 Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance
permeability up to class 4 Resistance to wind load up to class C4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal transmittance Uw > 1.5 W/m 2 K Mechanical strength class 4 Operating forces class [...] accordance with EN 14024 Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance FB4 up to FB6 TRAV RWA / NRWG
product standard EN 14351-1 Tightness against heavy rain up to class 4A Air permeability up to class 4 Resistance to wind load up to class C4/B4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal [...] with EN 12400 class 8 Burglar resistance in accordance with EN 1627 up to RC3 Bullet resistance FB 4-6 TRAV Emergency exit door in accordance with EN 1125 / EN 179
14351-1 Tightness against heavy rain up to class 8A Air permeability up to class 4 Resistance to wind load up to class C4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal transmittance Uw
strength class 4 Dangerous substances in accordance with ISO 16000 met Durability class 4 (50,000 cycles) Impact resistance class 4 Prefabricated glazing suitable for safety barrier loading DIN 18008-4 met Burglar [...] 14351-1 Resistance to wind load C5 (2000 Pa) Watertightness up to class 9A (600 Pa) Sound reduction up to 45 dB Thermal transmittance of Uf from 1.9 W/m2K Air permeability class 4 (600 Pa) Load-bearing capacity
Janisol 2 EI30 have been expanded with the installation depth 70 mm. In this way transparent Janisol C4 EI60 fire-resistant partitions - in the extreme case even EI90 fire-resistant partitions- can be combined
14351-1 Tightness against heavy rain up to class 6A Air permeability up to class 4 Resistance to wind load up to class C2/B2 Airborne sound insulation up to Rw 39 dB Shear bonding in accordance with EN [...] plastic Threshold profile made of glass-fibre reinforced plastic Element types Lift-and-slide 1, 2 or 4-leaf Different panel sizes possible Equipment Fittings up to 400 kg/leaf Special solution up to 600
fitted. The appearance of the Jansen Economy doors is identical with that of the Janisol 2 and Janisol C4 fire safety systems. The profiles of the 60 depth have very narrow face widths. Jansen Economy profiles [...] control in accordance with DIN 18095 Smoke control tested in accordance with EN 1634-3 Durability (C5) tested in accordance with EN 1191 Emergency exit door in accordance with EN 1125 / EN 179
insulation to 42 dB Tightness against heavy rain 9A (max. E 1050) Air permeability class 4 Resistance to wind load class B3/C3 Burglar resistance in accordance with EN 1627 for RC (WK) 3 Minergie-certified
diameter 63 mm Wall thickness 2.9 mm (SDR 22) Capacity 2.27 l/m pipe Operating temperature -20° C to +40° C Materials PE 100 RC (polyethylene resistant to cracking) Applications Heating Free cooling Hot [...] properties of these soils. Available options 1 pipe at a depth of 1.5 m 2 pipes at a depth of 1.5 m 4 pipes at a depth of up to 2 m Special versions possible Approvals / certifications SKZ Guideline HR [...] systems Fittings and electrically welded sleeves 1 JMA = Gemittelte Jahresaussenlufttemperatur; unter 8° C bzw. oberhalb einer Seehöhe von 800 m ist eine genauere Berechnung notwendig
~30 W/mK Inner tube Smooth tube 37 mm Pressure rating PN 7.4 Safety factor 1.25 Burst pressure 24.1 bar @ 20° C Buckling pressure 6 bar @ 20° C Volume per probe meter 1.9 l/m Special base diameter ø 66
-20° C to +40° C Rec. minimum laying temp. -10° C Dimensions Dimension Pressure rating Capacity per metre pipe 32 x 2.9 mm PN 16 0.517 l 40 x 3.7 mm PN 16 0.802 l 40 x 4.1 mm PN 18 0.762 l 40 x 4.5 mm [...] mm PN 20 0.725 l 50 x 4.6 mm PN 16 1.255 l 50 x 5.6 mm PN 20 1.135 l 50 x 6.9 mm PN 25 0.988 l 50 x 7.9 mm PN 30 0.881 l The modified inner surface finish results in a reduced filling volume. For this reason [...] Anti-freeze is expensive; with the JANSEN shark ground source heat systems, filling is also around 4 % less expensive than with conventional smooth pipes. Ground source heat loops With JANSEN shark technology
for dimension 50 mm 1000 mm @ 20° C 1750 mm @ 10° C 2500 mm @ 0° C Pressure ratings PN16, PN20, PN25, PN30 Safety factor 1.25 Volume per tube meter 5.23 l/m 4.73 l/m 4.12 l/m Approvals / certifications [...] Filling volume per m heat loop JANSEN vertex Single-U 50 x 4.6 mm; PN 16 250 to 300 m 5.231 l/m JANSEN vertex Doppel-U 50 x 5.6 mm; PN 20 250 to 350 m 4.73 l/m JANSEN vertex Doppel-U 50 x 7.9 mm PN 30 300 to
base ø Minimum bending radii at 20° C 32 x 2.9 mm SDR11 / S5 PN 16 60 - 170 m 101 mm 0.65 m 40 x 3.7 mm SDR11 / S5 PN 16 100 - 300 m 115 mm 0.80 m 40 x 4.5 mm SDR9 / S4 PN 20 200 - 325 m 115 mm 0.80 m Range [...] Black Material density ~ 0.95g/cm3 Pipe roughness 0.03 mm Recommended minimum laying temperature -10° C Approvals / certifications SKZ Guideline HR 3.26 SKZ quality seal A530 EN 10204-3.1 Material as per [...] on possible applications, please contact our technical advisers. 40 x 3.7 mm (dark green) and 40 x 4.5 mm (light green)
corrugated pipe ~30 W/mK Pressure rating PN 7.4 Safety factor 1.25 Burst pressure 24.1 bar @ 20° C Buckling pressure 6 bar @ 20° C Volume per probe meter 4.54 l/m Special base diameter Ø 130 mm
plant, week.year, Nat.Charge Nr., Arb. Nr. Example: Jansen nero under licence of Wavin PE80, ø 125 x 4.9, SSIV/VSA, JO 14.13 081547, 1983 Physical properties Melt index 0,3 - 0,89 g/10 min Coefficient of [...] drainage system is hot water resistant and fulfils the requirements of DIN EN 12056 and DIN 1986-100 (95° C short-time load). Industrial wastewater The JANSEN nero rainwater drainage system is resistant against
ideal for highly thermally insulated facade constructions with passive house certification. The Janisol C4 EI60 and Janisol 2 EI30 steel fire doors were also used on the new university campus. The highly thermally
wind load C5 (2000 Pa) Watertightness up to class 7A (300 Pa) Sound reduction up to 43 dB Thermal transmittance of Uf from 5.2 W/m2K Air permeability class 3 (600 Pa) Mechanical strength class 4
capacity of safety devices met Mechanical strength class 4 Impact resistance class 4 Prefabricated glazing suitable for safety barrier loading DIN 18008-4 met [...] 14351-1 Resistance to wind load C5 (2000 Pa) Watertightness up to class 9A (600 Pa) Sound reduction up to 47 dB Thermal transmittance of Uf from 1.9 W/m2K Air permeability class 4 (600 Pa) Load-bearing capacity
VISS RC3 system with a fire protection requirement of EI60 and equipped with heat-insulated Janisol C4 RC3 fire-proof doors. The VISS facades on the roof structure, which house a restaurant among other [...] – mirror panels, MVRDV Architekten opted for the Jansen VISS SG Facade system solution with the RC4 requirements. The 1664 mirrors, which were arranged in 26 rows of 64 mirrors that stretch all the way [...] way around the building, were manufactured in China and installed in the building in a VISS SG RC4 facade. What’s more, the seamlessly integrated automatic sliding doors in the entrance areas are a special
VISS RC3 system with a fire protection requirement of EI60 and equipped with heat-insulated Janisol C4 RC3 fire-proof doors. The VISS facades on the roof structure, which house a restaurant among other [...] – mirror panels, MVRDV Architekten opted for the Jansen VISS SG Facade system solution with the RC4 requirements. The 1664 mirrors, which were arranged in 26 rows of 64 mirrors that stretch all the way [...] way around the building, were manufactured in China and installed in the building in a VISS SG RC4 facade. What’s more, the seamlessly integrated automatic sliding doors in the entrance areas are a special
standards Fire resistance E45/EW45 Wind load resistance C4 (1600 Pa) Tightness against heavy rain of up to class 8A (450 Pa) Air permeability to class 4 (600 Pa) Load capacity of safety equipment fulfilled
Tightness against heavy rain up to class E750 Air permeability up to class 4 (600 Pa) Resistance to wind load up to class C4 (1600 Pa) Airborne sound insulation up to Rw 46 dB Heat transmission coefficient [...] EN 1627 to 1630 for RC1N to RC3 Prefabricated glazing suitable for safety barrier loading DIN 18008-4 met RWA / NRWG
AWS 75.SI and ADS 75.SI / HD.HI were used. Janisol HI doors , Jansen Economy , Janisol 2 and Janisol C4 fire and smoke doors were also used. HHL Architekten , Ludwigsburg/DE MBO Metallbau , Obersulm/DE AWS
up to Class 4 Impact resistance in accordance with EN 13049 up to Class 4 Durability in accordance with EN 12400 Class 7 (500,000) Prefabricated barrier glazing in accordance with DIN 18008-4 [...] Tightness against heavy rain up to Class 8A (450 Pa) Air permeability up to Class 4 (600 Pa) Resistance to wind load up to Class C5/B5 (2000 Pa) Airborne sound insulation up to Rw 45 db Heat transmission coefficient
Test certificates Tightness against heavy rain class 9A Resistance to wind load class C3/C4 Air permeability class 4 Burglar resistance in accordance with EN 1627 for RC (WK) 3
Test certificates Tightness against heavy rain class 9A Resistance to wind load class C3/C4 Air permeability class 4 Burglar resistance in accordance with EN 1627 for RC (WK) 3
made of steel provides 60 minutes of fire resistance around the atrium. Janisol 2 EI30 and Janisol C4 EI60 steel fire doors are integrated into this. Numerous Schüco Alumnium systems, such as the Schüco
infrastructure on a total of eight floors. Fire protection plays a vital role; Janisol 2 EI30 and Janisol C4 EI60 came into use. Lüscher Architekten AG , Zurich/ CH Axess Architekten AG , Zug/ CH Hobler Metallbau
The exhibition presents the projects of the 362 nominated works of the best European architecture of the last two years. These works stem from 38 European countries, 125 regions and 240 locations. Aft
02: Frame production work steps 01 Weld seam preparation With the example of a Jansen Janisol C4 fire safety profile - exception of fire safety compound - bevelling 02 Drop-latch lock recess and fitting
insulation up to 45 dB Air permeability Class 4 Tightness against heavy rain 8A Wind load resistance Class C3/B3A3 Durability Class 7 Impact resistance Class 4 Operating forces Class 2 CE label yes BIM model
Inc., 1 Hacker Way, Menlo Park, CA 94025, USA or, if you are based in the EU, Facebook Ireland Ltd., 4 Grand Canal Square, Grand Canal Harbour, Dublin 2, Ireland (‘Facebook’) is used on our website. Facebook [...] affected person as well as for carrying out corresponding pre-contract measures. Art. 6 section 1 lit. c GDPR for the required processing of personal data for the fulfilment of a legal obligation that we are
situations The assessment of glass building elements that serve as barriers is governed by DIN 18008 Part 4, which is concerned with the impact resistance of the laminated safety glass LSG and with the load-bearing [...] A (the glazing is the sole anti-fall protection means), B (a continuous rail is also provided) and C (the glazing merely has an infill function). Building without barriers Automatic doors, entrances without [...] climate in order from points a to e; class d, for example, is based on a temperature differential of 40°C. Doors in class 3 (d), however, suffer a maximum distortion in length and width of four millimetres
by means of fixed glazing with Janisol 2 EI30 and double-leaf glass doors Janisol C4. The thermally insulated Janisol C4 fire door adds further fire protection with an innovative ceramic filling in sop [...] Text - Referenzlandingpages - EN The concept is supported by the Jansen Janisol 2 EI30 and Janisol C4 EI90 products. With Janisol 2, multifunctional transparent internal attachments and partition walls
invests in the Oberriet site 2024-10-29 https://mediacenter.jansen.com/shared/assets/79d909fceb71b15096f4 Jansen sets course for the future 2024-10-08 https://mediacenter.jansen.com/shared/assets/7dc6304d2 [...] products for the construction sector. 2021-01-13 https://mediacenter.jansen.com/shared/assets/98550c963bacd40fcd65 Jansen is taking over RP Technik from the Welser Profile Group 2021-01-05 https://mediacenter [...] Schüco and Soreg combine expertise 2018-01-11 https://mediacenter.jansen.com/shared/assets/e024d32ea48756c2a767
remaining quantity must be stated in writing. 4.4 Before the expiry of the delivery deadline, Jansen AG is entitled, but not obliged, to accept the goods. 4.5 Benefit and risk pass to Jansen AG upon completion [...] only assign the purchase price receivable with prior consent from Jansen AG. 4 Delivery and delivery periods, transfer of risk 4.1 The delivery period stated in the order and other delivery dates agreed in [...] AG. 4.10 The Supplier shall ensure that all deliveries subject to mandatory marking are properly marked. The marking shall also be shown on order confirmations and all other shipping documents. 4.11 The
a pivot window, the window only rotates on its own vertically mounted axis of rotation when opened. 4. Projected top-hung windows Projected top-hung windows are top-hung windows that can be opened outwards [...] centrally or off-centre and can be pivoted. This means that even very large door leaves can be used. 4. Sliding doors For sliding doors, there are various more detailed designations depending on the opening [...] elements. Depending on the type of arrangement, a distinction is made between different schemes (A, B, C etc.). 5. Folding sliding doors Folding sliding doors generally run along rails and can result in very
incomparable strength of steel lies in its high melting temperature. With values between 1250°C and 1400°C, steel sets its own standards and clearly outperforms other materials such as wood, PVC, and aluminum [...] solution for fire protection. The most important facts in a nutshell: High melting temperature: 1250°C – 1400°C. Optimum fire protection: Combination of steel with glass and/or panels. Learn more about Fire [...] rigorous tests to provide unsurpassed burglar resistance. In the facade certified with resistance class RC4 – a testament to quality and confidence. Recognize the advantages of steel. A material that harmonizes
conductivity, but also unearthed a special hydrogeological situation: During the TRT, temperatures of 45°C were measured at a depth of 120 m. This meant that only high-temperature geothermal systems that are [...] t PE-RT . From the probes to the heat pumps via the chambers: a complete system that allows for 45°C water to be circulated constantly for a service life of 50 years. Due to the foundations no geothermal [...] other. The probes are connected via six manifold chambers; the largest chamber holds 55 circuits and is 4.5 metres long. Jansen: supplier and partner Jansen fulfilled all of the requirements from the geothermal