bullet resistance and EXR 3 explosion resistance, all packaged neatly into one profile: the Economy 60 system from Jansen. Samyn and Partner , Brussels/BE Studio Valle Progettazioni , Rome/IT Buro Happold
glazing were used for the facade. In the interior, individual FWS 50 glass facades and Jansen Janisol 60 steel doors were also used. AWS 90.SI + FWS 50 Utopia Arkitekter AB , Stockholm/SE 2016 SE-Uppsala
for the VISS SG profile system with a profile depth of just 150 millimetres and a slim face width of 60 millimetres. With VISS SG , the Swiss company Jansen AG offers an architecturally high-quality solution
The result is an unpretentious building with a surrounding facade made of highly static Jansen VISS 60 profiles which reaches seven to seven-and-a-half metres, and makes a clear and distinctive statement [...] statement in this mixed urban area. The architect consciously opted for the highly static Jansen VISS 60 profile system: “We were looking for an elegant solution, and the metalworker drew our attention to this [...] were won over straight away by the surprisingly narrow face width.” With the highly static Jansen VISS 60 profiles, it was possible to continue the supporting structure of the shell, which was kept as minimal
mm Leaf heights up to 2'900 mm Special technical features Installation depth, leaf 60 mm Installation depth, frame 60 mm Infill elements, 13 - 37 mm Face width from window overlap area 105 mm Face width
in face widths of 50 and 60 mm . In addition, thanks to VISS Basic, any type of support profile can be used. Insert elements from Janisol , Janisol Arte and Jansen Economy 50/60 with corresponding RC approval [...] technical features VISS RC can be combined with the existing VISS systems in face widths of 50 and 60 mm VISS RC versions can be combined with the burglar resistant profile solutions of the Janisol door
Fire doors and fire-resistant partitions of class E30/EW30/E60/EW60 can be easily assembled using the tried-and-tested Economy profiles. It is even possible to achieve fire resistance classes up to E120 [...] without fire protection ( Jansen Economy 50 door ). Test certificates Fire resistance class E30/EW30/E60/EW60 for doors and up to E120 for fixed glazing; tested in accordance with EN 1634-1 Smoke control in [...] narrow face widths. The appearance is identical to that of the other fire protection systems Economy 60, Janisol 2 and Janisol C4. Materials / surface Uncoated or strip-galvanised steel, suitable for powder
0° to 80°) Test certificates Fire protection class RE30, REW30, REI30, RE45, REW45, REI45, RE60, REW60, REI60 EI30 fire protection class CE marking based on product standard 13830 (water quantity 3l/m rather [...] all types of roofs as safe fire-resistant roof glazing. Of course, the new approvals also include our 60 mm profile widths. Materials/surface finishes Uncoated or strip-galvanised steel, suitable for powder
or only with fire protection ( Fire protection doors Jansen Economy 60 ). Also possible without smoke protection ( Jansen Economy 60 door ). Test certificate Smoke control in accordance with DIN 18095 [...] allow a rational production of flush smoke control doors according to DIN 18095. The profiles of the 60 depth are characterised by the narrow face widths. Many different styles and functional variations
infill panels With integrated espagnolette bolt Special technical features Construction depths 50, 60, 80 mm Sliding doors can be supplied with top or bottom tracks Installation behind, between or in front
walls Equipment Steel and stainless steel hinges for welding or screw-fit Integrated door closers for EI60 Multipoint locks (motorised also available) Designer glazing beads Emergency locks and panic push-bars [...] putty Door heights up to 2.50 m with single-latch lock Test certificates Fire resistance classes EI60 and EI90 tested in accordance with EN 1634-1 and DIN 4102-5 Partition wall EI120 Smoke control in
Installation depth 60 mm Special geometries (semi-circular tops) Also available as anti-finger-trap door Also available with fire protection ( Fire protection doors Jansen-Economy 60 ) or smoke protection [...] Thanks to its greater installation depth and wall thickness, the Jansen-Economy 60 system is particularly suitable for large, heavy duty single and double doors and for applications requiring higher levels [...] protection ( Smoke control doors Jansen-Economy 60 RS ). Test certificates CE marking in accordance with product standard EN 14351-1 Tightness against heavy rain up to class 4A Air permeability up to class 4
fittings Integrated or surface-mounted electric drives Special technical features Installation depth 60/64 mm Special geometries (semi-circular tops, trapezoidal windows etc.) Structural glazing panel as
Designer glazing beads Emergency locks and panic push-bars Special technical features Installation depth 60 mm Special geometries (semi-circular tops) Structural glazing leaf as special solution Pivot door made
With only 60 mm installation depth, the thermally broken steel profiles achieve excellent thermal insulation values and make an active contribution to environmentally compatible sustainable building. The [...] fittings Integrated or surface-mounted electric drives Special technical features Installation depth 60/64 mm Special geometries (semi-circular tops, trapezoidal windows etc.) Structural glazing panel as
Electric drive Special technical features Basic depth of 60 mm Very narrow face widths Fixed glazing 25 mm Window vent 20 mm Window meeting stile design 60 mm Easy to fabricate Window sizes up to 1000 x 2400 [...] With the narrowest profile face widths of only 25 or 40 mm for fixed glazing and a basic depth of 60 mm, intricate yet stable constructions with a large proportion of glass and excellent thermal insulation
Janisol 2 EI30 have been expanded with the installation depth 70 mm. In this way transparent Janisol C4 EI60 fire-resistant partitions - in the extreme case even EI90 fire-resistant partitions- can be combined [...] multipoint locking Test certificates Tested in accordance with EN 1634-1 Fire resistance class EI30/EI60/EI90 Emergency exit door in accordance with EN 179 / 1125 Swiss fire protection applications
accordance with DIN 18650. Thanks to low-maintenance, high-performance hinge bearings, the Jansen Economy 60 anti-finger-trap doors are particularly suitable for buildings with heavy public use such as shopping [...] and installation of fittings Straightforward and cost-effective thanks to the usage of Jansen-Economy 60 profiles from the standard range
with integrated emergency exit function: 1250 x 2500 mm and 2400 x 2500 mm Installation in El30, El60, El90 partition walls Element sizes depending on system arrangement: height up to 4040 mm and width
construction techniques possible Equipment Insert doors Special technical features Face width of 50 and 60 mm Construction depths from 50 mm to 280 mm Filling element thickness from 15 mm to 70 mm Test cer
control doors Jansen Economy 60 RS ). Also possible without fire protection, see link for details ( Jansen Economy 60 door ). Test certificates Fire resistance class E30/EW30/E60/EW60 Smoke control in accordance [...] With the well-known Jansen Economy profiles class E30/EW30/E60/EW60 fire doors and fixed lights up to class E90 can be fitted. The appearance of the Jansen Economy doors is identical with that of the Janisol [...] Janisol 2 and Janisol C4 fire safety systems. The profiles of the 60 depth have very narrow face widths. Jansen Economy profiles allow smoke protection system components with cost-effective flush smoke
features Special shapes and radii down to 250 mm Installation depth 64 / 74 / 84 mm (glass thickness up to 60 mm) Flush inside and outside Internal and external glazing Sliding doors glazed to threshold Test
The Jansen VISS SG system can be readily combined with all VISS profiles with face widths of 50 and 60 mm, as well as with the VISS Basic solution, which can be mounted on any support. With steel as the [...] doors must be detailed specifically for each project Special technical features Face widths 50 and 60 mm Installation depths 50 to 250 mm Infill element thickness 30 to 70 mm VISS Semi SG Approvals ETA
Test certificates Tested in accordance with EN 1364 Fire protection classes E30 / E60 Fire protection classes EI30 / EI60 / EI90 TRAV Product standard curtain wall in accordance with EN 13830 Clamp connection [...] and smoke. Numerous projects and a host of international tests and approvals in classes E30, EI30, EI60, EI90 attest the reliability of VISS Fire with respect to thermal insulation and fire protection.
technical features CE identification possible according to EN 1090 (EXC1 and EXC2) Face width 50 and 60 mm Filling element thickness 16 - 70 mm Uf values up to 0.64 W/m2K Building depths 50 - 280 mm Roof
couples, gable glazing, polygon glazing Pent roof glazing Special technical features Face width 50 and 60 mm Installation depth to meet structural engineering requirements Thickness of infill elements, 16
solar screening devices Windows and doors can be fitted Special technical features Face width 50 and 60 mm Thickness of infill elements, 6 to 70 mm Construction depths 50 to 280 mm Test certificates CE marking
Intelligent pipe technology: refined symbiosis of nature and engineering With more than 60 years of experience in the development and manufacture of innovative plastic systems, Jansen, as a Swiss industrial
Pressure rating Special lengths Special base ø Minimum bending radii at 20° C 32 x 2.9 mm SDR11 / S5 PN 16 60 - 170 m 101 mm 0.65 m 40 x 3.7 mm SDR11 / S5 PN 16 100 - 300 m 115 mm 0.80 m 40 x 4.5 mm SDR9 / S4
63 mm 16 - 32 mm 16 - 32 mm 16 und 20 mm 16 x 2.0 20 x 2.0 26 x3.0 32 x 3.0 40 x 3.5 50 x 4.0 63 x 6.0 Kl 1-5 10 bar Kl 1-5 10 bar Kl 1-5 10 bar Kl 1-5 8 bar Kl 1-5 8 bar Kl 1-5 10 bar Kl 1-5 10 bar
reinforced with rear-sulphur slats. The gallery is divided in sections by glass fixtures with VISS Fire (EI60) and Janisol 2 profiles (EI30) – with semicircular skylight analogous to the vault of the gallery.
systems Window systems Janisol door Janisol window Fire doors Janisol 2 EI30 Smoke control door Economy 60 Nike Fiedler Architekten PartG mbB , Stuttgart/DE Vetter Stahl-Metallbau GmbH , Endingen am Kaiserstuhl/DE
highly thermally insulated facade constructions with passive house certification. The Janisol C4 EI60 and Janisol 2 EI30 steel fire doors were also used on the new university campus. The highly thermally
inner facades have been installed in the Jansen VISS RC3 system with a fire protection requirement of EI60 and equipped with heat-insulated Janisol C4 RC3 fire-proof doors. The VISS facades on the roof structure
thermally separated VISS EI30 post and mullion structure has now been tested with frame widths of 50 mm and 60 mm – thus ensuring that virtually no wishes are left unfulfilled in terms of the choice of the glazing
inner facades have been installed in the Jansen VISS RC3 system with a fire protection requirement of EI60 and equipped with heat-insulated Janisol C4 RC3 fire-proof doors. The VISS facades on the roof structure
for window applications as well as E/EW30 for fixed glazing. The window has an installation depth or 60 mm (window frame) or 64 mm (window casement) and has the same face as the Janisol window. It also impresses [...] fitting up to 150kg Lockable aluminium window handle Special technical features Installation depth of 60 mm (window frame) or 64 mm (window casement) Window casement of up to 1265 x 2300 mm Filling element
along with a multitude of international tests and authorisations in classes E/EW30–E/EW90, EI30 and EI60, demonstrate the reliability of the VISS facade in its many versions, in terms of protection from both
in terms of hygiene. The system also provides fire protection up to the EI30 standard. With Economy 60 , buildings or building sections that do not require thermal insulation can be secured against burglary
are also constructed using Jansen Economy 60. The proven burglar resistance and mechanical strength of the steel profile system with a construction depth of 60 millimetres is particularly appreciated in [...] of the building also extend to room-height window sashes at each end. Thanks to the Jansen Economy 60 steel profile system and its slender design, the casements impress with their vast glass surfaces and
with profile face widths of 25 and 40 millimetres in the fixed glazing and a construction depth of 60 millimetres is an impressive solution for robust designs with a high proportion of glass and the thermal
glazing beads Mortise lock and multipoint lock Special technical characteristics Construction depth 60 mm All-glass look Test certificates CE label in accordance with product standard EN 14351-1 Tightness
transom facades on the staggered floors using the VISS facade steel profile system. With a face width of 60 millimetres, the VISS facade accommodates the enormous glass panes – measuring up to 3708 x 3000 m
storey-high Jansen VISS Fire TVS EI60 mullion-transom façade made of steel provides 60 minutes of fire resistance around the atrium. Janisol 2 EI30 and Janisol C4 EI60 steel fire doors are integrated into [...] Statik Thomas Lorenz ZT GmbH , Graz/AT FWS 50.SI, AWS 75.SI+ AOC 50 ST, ADS 75.SI ADS 65 NI, ADS 80 FR 60 ADS 80 FR 30, ADS 65 NI FR 30 AT-Vienna
re on a total of eight floors. Fire protection plays a vital role; Janisol 2 EI30 and Janisol C4 EI60 came into use. Lüscher Architekten AG , Zurich/ CH Axess Architekten AG , Zug/ CH Hobler Metallbau
Dimensions (WxDxH) 1200 mm x 600 mm x 630 mm Net volume 436 litres max. per unit Max. load capacity SLW 60 The components, consisting of a base plate , storage element and side plates, are assembled by Jansen
With a view of the Golden Mile A new hotel concept plays with the quest for individuality. The idea of combining the comfort of a modern city hotel with the independence of an apartment embraces the n