Manufactured length 110 mm 3.8 mm 102.4 mm 6 m 125 mm 4.3 mm 116.4 mm 6 m 160 mm 5.5 mm 149.0 mm 6 m 200 mm 6.9 mm 186.2 mm 6 m 250 mm 8.6 mm 232.8 mm 6 m 315 mm 10.8 mm 293.4 mm 6 m 400 mm 13.7 mm 372
the maximum possible sizes and the feasible transparency of structures with a span width of up to 4.3 metres are impressive (fire-resistant roof glazing). In a construction with a VISS roof standard, the
10 x 1.3 12 x 1.3 14 x 2.0 16 x 2.0 17 x 2.0 18 x 2.0 20 x 2.0 26 x 3.0 32 x 3.0 Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/4 bar Kl 5/4 bar Kl 4/8 bar Kl 5/6 bar Kl 4/8 bar Kl 5/6 bar Kl 4/6 bar [...] bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar
Coils Coils pre-insulated 12 to 26 12 x 1.3 14 x 2.0 16 x 2.0 18 x 2.0 20 x 2.0 26 x 3.0 KL 4/5 10 bar KL 4/5 10 bar Kl 4/5 10 bar Kl 4/5 10 bar Kl 4/5 10 bar Kl 4/5 10 bar
12 x 1.3 14 x 2.0 14.5 x 1.8 15 x 1.5 15 x 2.5 16 x 2.0 17 x 2.0 18 x 2.0 20 x 2.0 KI 4/10 bar KI 5/8 bar KI 4/10 bar KI 5/8 bar KI 4/5 10 bar KI 4/5 10 bar KI 4/5 10 bar KI 4/8 bar KI 5/6 bar KI 4/5 10 [...] 10 bar KI 4/5 10 bar KI 4/5 10 bar KI 4/5 10 bar KI 4/10 bar KI 5/8 bar [...] their excellent flexibility and durability in thermally and mechanically challenging conditions. The PB 3-layer pipe has an outer layer of EVOH, an oxygen barrier. Advantages Suitable for high- and low-temperature
inner facades have been installed in the Jansen VISS RC3 system with a fire protection requirement of EI60 and equipped with heat-insulated Janisol C4 RC3 fire-proof doors. The VISS facades on the roof structure [...] – mirror panels, MVRDV Architekten opted for the Jansen VISS SG Facade system solution with the RC4 requirements. The 1664 mirrors, which were arranged in 26 rows of 64 mirrors that stretch all the way [...] way around the building, were manufactured in China and installed in the building in a VISS SG RC4 facade. What’s more, the seamlessly integrated automatic sliding doors in the entrance areas are a special
15876 SKZ-A141 Variants Dimensions Coils 10 to 16 mm 10 x 1.0 12 x 1.3 15 x 1.5 16 x 2.0 KI 4/5 8 bar KI 4/5 10 bar KI 4/5 8 bar KI 4/5 10 bar [...] excellent flexibility and durability in thermally and mechanically challenging conditions. The FUTURA PB 3-layer pipe has an outer layer of EVOH, an oxygen barrier. Advantages Only for low-temperature applications
levels of building protection, Jansen presents the new VISS RC4, a further development of its RC3 burglar resistant system. With VISS RC4, Jansen is meeting the growing need for solutions that offer increased [...] VISS facade, the VISS RC4 structure shows no visible signs of burglar resistance. This allows different building requirements to be realised with a uniform appearance. New VISS RC4 facade also provides [...] The VISS RC4 facade can withstand the standardised break-in attempt in accordance with EN 1630 for at least ten minutes. The VISS facade can be upgraded to a burglar-resistant structure up to RC4 with just
Material density ~ 0.95g/cm3 Pipe roughness 0.03 mm Recommended minimum laying temperature -10° C Approvals / certifications SKZ Guideline HR 3.26 SKZ quality seal A530 EN 10204-3.1 Material as per PAS 1075 [...] 20° C 32 x 2.9 mm SDR11 / S5 PN 16 60 - 170 m 101 mm 0.65 m 40 x 3.7 mm SDR11 / S5 PN 16 100 - 300 m 115 mm 0.80 m 40 x 4.5 mm SDR9 / S4 PN 20 200 - 325 m 115 mm 0.80 m Range of products You will find [...] have any questions on possible applications, please contact our technical advisers. 40 x 3.7 mm (dark green) and 40 x 4.5 mm (light green)
Tested in accordance with EN 1364-1 and EN 1364-3 Classified according to 13501-2 AbP P-2020/001 fall-protection glazing AbZ Z-14.4-465 clamp connection AbZ Z-14.4-467 mullion-transom connection CE marking according [...] the VISS Fire facade EI30 RC2/3. This system combines an EI30 fire protection class, which guarantees a 30-minute fire resistance, with burglary protection classes RC2 and RC3, offering protection against [...] heavy tools (RC3). This combination ensures that the facade offers reliable protection both in the event of a fire and in case of an attempted break-in. The VISS Fire Facade EI30 RC2/3 has been specially
Bahnhofstrasse
40m
34m
1
2
34
P2
P1
Z
o
ll
am
t
O
b
er
ri
et
Tr
an
si
t
cu
st
o
m
o
f�
ce
Spedition Kunststoff
Logistics plastics
Autobahn/Motorway
4
Jansen AG | CH-9463 Oberriet [...]
(A
1
3
)
G
HP
C
B
A
R
Q
E
D
F
J
M
K
L
T
A14
A12
A15
B
ah
n
h
o
f/
st
at
io
n
A
lt
st
ät
te
n
B
uc
h
s
In
d
u
st
ri
es
tr
as
se
St
aa
ts
st
ra
ss
e
P4
im Kessler [...] 91 11
1 Kunststoff / plastics
2 Zentralmagazin / main warehouse
Eichaustrasse 7b
3 Halle / hall J
Eichaustrasse 7c
4 Bandstahl / coils
Halle / hall B
Halle / hall L
Parkplatz / car park
Eingang / entrance
product standard EN 14351-1 Tightness against heavy rain up to class 4A Air permeability up to class 4 Resistance to wind load up to class C4/B4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal [...] in accordance with EN 12400 class 8 Burglar resistance in accordance with EN 1627 up to RC3 Bullet resistance FB 4-6 TRAV Emergency exit door in accordance with EN 1125 / EN 179 [...] stations, banks and hotels. Security is becoming increasingly important. Burglar resistance up to RC3 is often prescribed for public buildings, but this need for protection is also increasingly observed
for 100 years Easy to work with on site 2-part design Total length 135 mm Transition Ø42 x 3.5 mm to Ø40 x 3.7 mm 4 pieces / plastic bag Rotary pipe cutter or pipe shears Rounding mandrel Measuring tool, [...] tying process safe, fast, efficient and cost-effective. The crimp sleeves are made of high-quality V4A stainless steel (1.4571), while the connector sleeves are made of glass fiber-reinforced high-performance [...] any time by trained personnel from the drilling company or the tying company Safe, quick, efficient V4A stainless steel 1.4571 press sleeves Connector sleeves made of glass fiber reinforced, high-performance
PN25, PN30 Safety factor 1.25 Volume per tube meter 5.23 l/m 4.73 l/m 4.12 l/m Approvals / certifications SKZ Guideline HR 3.26 EN 10204-3.1 Material as per PAS 1075 Associated products Injection pipes [...] JANSEN vertex Single-U 50 x 4.6 mm; PN 16 250 to 300 m 5.231 l/m JANSEN vertex Doppel-U 50 x 5.6 mm; PN 20 250 to 350 m 4.73 l/m JANSEN vertex Doppel-U 50 x 7.9 mm PN 30 300 to 400 m 3.67 l/m
inner facades have been installed in the Jansen VISS RC3 system with a fire protection requirement of EI60 and equipped with heat-insulated Janisol C4 RC3 fire-proof doors. The VISS facades on the roof structure [...] – mirror panels, MVRDV Architekten opted for the Jansen VISS SG Facade system solution with the RC4 requirements. The 1664 mirrors, which were arranged in 26 rows of 64 mirrors that stretch all the way [...] way around the building, were manufactured in China and installed in the building in a VISS SG RC4 facade. What’s more, the seamlessly integrated automatic sliding doors in the entrance areas are a special
remaining quantity must be stated in writing. 4.4 Before the expiry of the delivery deadline, Jansen AG is entitled, but not obliged, to accept the goods. 4.5 Benefit and risk pass to Jansen AG upon completion [...] time of design approval. 16.3 Prices and terms of payment 16.3.1 Unless otherwise agreed, the following terms of payment shall apply for equipment: 30 days after commissioning 16.3.2 For partial payments prior [...] associated digital 3D model: *.iam / *.ipt (Inventor) ansonsten *.stp (STEP AP214) oder *.igs (IGES) A 3D model of the entire equipment is to be provided. A simplified, data-reduced 3D model with correct
certification Tested in accordance with the EN 1364-1 and EN 1364-3 Classified in accordance with 1525-4 AbZ Z-14.4-465 clamp connection AbZ Z-14.4-467 post and mullion connection National approvals
accordance with product standard EN 13241-1 Tightness against heavy rain up to class 3 Air permeability up to class 4 Resistance to wind load up to class 5 Operating forces and user safety in accordance [...] product standard EN 13241-1 Tightness against heavy rain up to class 3 Air permeability up to class 1 Resistance to wind load up to class 4 Operating forces and user safety in accordance with EN 12453
rain up to class E900 Air permeability up to class 4 Resistance to wind load up to class C4/B4 Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance FB6 S/NS
class 4 Prefabricated glazing suitable for safety barrier loading DIN 18008-4 met Emergency exit door in accordance with EN 1125 / EN 179 Burglar resistance in accordance with EN 1627 up to RC 3 [...] 14351-1 Tightness against heavy rain up to class 9A Air permeability up to class 4 (600 Pa) Resistance to wind load up to class C4 (1600 Pa) Airborne sound insulation up to Rw 45 db Coefficient of thermal t [...] up to 57 mm (triple glazing) Very good structural values, narrow face widths Door leaf sizes up to 3.0 m Special geometries (semi-circular tops) Test certificates CE marking in accordance with product
insulation can be secured against burglary to class RC3. In windows, too, Jansen steel profile systems can meet various requirements for burglar resistance (to RC3) and heat insulation. The intricate Janisol Arte [...] shortly be launching a further development of its VISS facade system offering burglar resistance to RC3 and RC4. With an identical appearance to the standard VISS facade, the structure shows no visible signs [...] New to the market is the Janisol 2 multifunctional door , with burglar resistance tested to RC3 and anti-panic function. This allows for complete automation so that it can be used without requiring any
to class 4A Air permeability up to class 4 Resistance to wind load up to class C5 Sound insulation up to 44 dB Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance FB 4-6 S/NS [...] S/NS Emergency exit door in accordance with EN 1125 / EN 179 Mechanical strength class 4 Conditions for approval fulfilled Conditions for supporting safety devices fulfilled
permeability up to class 4 Resistance to wind load up to class C4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal transmittance Uw > 1.5 W/m 2 K Mechanical strength class 4 Operating forces class [...] in accordance with EN 14024 Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance FB4 up to FB6 TRAV RWA / NRWG
bending radius 0.45 m @ 20° C Pressure rating PN 7.4 Safety factor 1.25 Burst pressure 24.1 bar @ 20° C Buckling pressure 6 bar @ 20° C Volume per probe meter 4.54 l/m Special base diameter Ø 130 mm [...] sealing. Both advantages also beneficial to the system over its service life. Certification SKZ-HR 3.44, SKZ A698 Material PE 100 RC Pipe type JANSEN powerwave Wellrohr 63 x 2.9 mm Coefficient of thermal
Janisol Arte 2.0 door VISS RC4 burglar-resistant facade VISS RC4 burglar-resistant facade, media information german VISS RC4 burglar-resistant facade, media information english VISS RC4 burglar-resistant facade [...] Janisol HI (24 MB) VISS RC4 einbruchhemmende Fassade VISS RC4 einbruchhemmende Fassade, Medieninformation DE VISS RC4 einbruchhemmende Fassade, Medieninformation EN VISS RC4 einbruchhemmende Fassade, [...] media information french VISS RC4 burglar-resistant facade, media information italian VISS RC4 burglar-resistant facade, media information spanish Pictures: VISS RC4 burglar-resistant facade Motor-driven
t 0,18 mm/mK Serie 12.5 / SDR 26, SN4 Dimension dn Wall thickness en Internal diameter di Manufactured length 110 mm 4.2 mm 101.6 mm 6 and 10 m 125 mm 4.8 mm 115.4 mm 6 and 10 m 160 mm 6.2 mm 147.6 mm [...] 6 mm 6 and 10 m 315 mm 9.7 mm 295.6 mm 6 and 10 m 355 mm 10.9 mm 333.2 mm 6 and 10 m 400 mm 12.3 mm 375.4 mm 6 and 10 m [...] Available options With integrally formed expansion coupling or smooth ends Annular rigidity SN 2 / SN 4 Connection devices With integrally formed push-fit connector Fittings are available fully moulded and
up to Class 4 Impact resistance in accordance with EN 13049 up to Class 4 Durability in accordance with EN 12400 Class 7 (500,000) Prefabricated barrier glazing in accordance with DIN 18008-4 [...] can be opened inwards and outwards Sheet metal-clad doors with or without glass cut-outs Equipment 3D screw-on hinges made of stainless steel Integrated door closer Designer glazing beads Mortise lock [...] standard EN 14351-1 Tightness against heavy rain up to Class 8A (450 Pa) Air permeability up to Class 4 (600 Pa) Resistance to wind load up to Class C5/B5 (2000 Pa) Airborne sound insulation up to Rw 45 db
Resistance to wind load class C4 Tightness against heavy rain class E1050 Air permeability class 4 Uw 1.2 W/m²K - 1.35 W/m²K Burglar resistance in accordance with EN 1627 for RC (WK) 3
CH standard) Uw 0.78 to 1.3 W/m 2 K Airborne sound insulation to 42 dB Tightness against heavy rain 9A (max. E 1050) Air permeability class 4 Resistance to wind load class B3/C3 Burglar resistance in accordance [...] accordance with EN 1627 for RC (WK) 3 Minergie-certified
Beuningen VISS SG facade in RC4 (object solution) Khi House Jansen Economy 60 (possible until RC3 ) JVA Cazis Tignez Jansen Economy 60 und Fire door Janisol 2 EI30 in R3 Products burglar resistance Doors [...] class RC3 offer greater levels of protection: They must withstand at least five minutes of crowbar assault. Experience has shown that burglars give up the longer the building part resists. RC4 to RC6 are
Tightness against heavy rain up to class 8A (450 Pa) Air permeability up to class 4 Resistance to wind load up to class C3/B3 Operating forces class 1 Airborne sound insulation up to Rw 45 dB
Coils in the conduit 16 x 63 mm 16 - 32 mm 16 - 32 mm 16 und 20 mm 16 x 2.0 20 x 2.0 26 x3.0 32 x 3.0 40 x 3.5 50 x 4.0 63 x 6.0 Kl 1-5 10 bar Kl 1-5 10 bar Kl 1-5 10 bar Kl 1-5 8 bar Kl 1-5 8 bar Kl 1-5
14351-1 Tightness against heavy rain up to class 8A Air permeability up to class 4 Resistance to wind load up to class C4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal transmittance Uw [...] Shear bonding in accordance with EN 14024 Burglar resistance in accordance with EN 1627 up to RC (WK) 3 TRAV RWA / NRWG
Exter ior des ign .
Per-panel ventilation not permitted with RC3/4 and FB3/4 security classes
In previous versions, the RC3/4 and FB3/4 security classes could be selected in the element parame-
ters [...] Exter ior des ign .
Per-panel ventilation not permitted with RC3/4 and FB3/4 security classes
In previous versions, the RC3/4 and FB3/4 security classes could be selected in the element parame-
ters [...] .. 27
6.4.3 Schüco VentoFrame Twist window vent: pre-treatment for maritime climate ............. 27
Documentation Version 2023 R3
English January 2024 Page 3 of 64
JANIsoft 2023 R3
Page
profiles allows for particularly filigree interior views. Large-format glass surfaces measure up to 3.5 x 2.4 metres, visibly increasing the transparency of the building envelope. The facade can be partially
Tightness against heavy rain up to class E750 Air permeability up to class 4 (600 Pa) Resistance to wind load up to class C4 (1600 Pa) Airborne sound insulation up to Rw 46 dB Heat transmission coefficient [...] EN 14024 Tests in accordance with EN 1627 to 1630 for RC1N to RC3 Prefabricated glazing suitable for safety barrier loading DIN 18008-4 met RWA / NRWG
fitted. The appearance of the Jansen Economy doors is identical with that of the Janisol 2 and Janisol C4 fire safety systems. The profiles of the 60 depth have very narrow face widths. Jansen Economy profiles [...] putty Central glazed panel Connection to solid wall or lightweight wall construction Door height up to 3.8 m with single-latch lock possible Also possible with fire protection and smoke protection combined [...] 60/EW60 Smoke control in accordance with DIN 18095 Smoke control tested in accordance with EN 1634-3 Durability (C5) tested in accordance with EN 1191 Emergency exit door in accordance with EN 1125 / EN
appearance is identical to that of the other fire protection systems Economy 60, Janisol 2 and Janisol C4. Materials / surface Uncoated or strip-galvanised steel, suitable for powder coating or stove-enamelling [...] putty Central glazed panel Connection to solid wall or lightweight wall construction Door height up to 3.8 m with single-latch lock possible Also possible with fire protection and smoke protection combined [...] EN 1634-1 Smoke control in accordance with DIN 18095 Smoke control tested in accordance with EN 1634-3 Durability (C5) tested in accordance with EN 1191 Emergency exit door in accordance with EN 1125 / EN