area opens up to the floors by means of fixed glazing with Janisol 2 EI30 and double-leaf glass doors JanisolC4. The thermally insulated JanisolC4 fire door adds further fire protection with an innovative [...] Nur Text - Referenzlandingpages - EN The concept is supported by the JansenJanisol 2 EI30 and JanisolC4 EI90 products. With Janisol 2, multifunctional transparent internal attachments and partition walls
area opens up to the floors by means of fixed glazing with Janisol 2 EI30 and double-leaf glass doors JanisolC4. The thermally insulated JanisolC4 fire door adds further fire protection with an innovative [...] square meters, designed for the working world of the future. Janisol 2 EI30 and JanisolC4 doors were installed in the "Pergamin II" building. Janisol 2 made it possible to create multifunctional transparent [...] area. There were several reasons why Jansen was awarded the contract: On the one hand, the technical advice and service were right, and on the other hand, the JANSEN geotwin double U probes were easy and
With the example of a JansenJanisolC4 fire safety profile - exception of fire safety compound - bevelling 02 Drop-latch lock recess and fitting Mark G-size - use of the Jansen drilling gauges - drill
and Jansen were used. For the glass façade, the Jansen VISS façade system was used, which is ideal for highly thermally insulated façade constructions with passive house certification. The Janisol C4 EI60 [...] EI60 and Janisol 2 EI30 steel fire doors were also used on the new university campus. The highly thermally insulated Janisol HI system was installed for doors and windows. Read more in the online magazine
window construction; Schüco AWS 75.SI and ADS 75.SI / HD.HI were used. Janisol HI doors , Jansen Economy , Janisol 2 and JanisolC4 fire and smoke doors were also used. HHL Architekten , Ludwigsburg/DE [...] element in the staircase, which connects the town hall and the media library, are glazed with the Jansen VISS 50 mullion-transom façade. The reason for this was the architects' wished for a filigree co
glazed inner façades have been installed in the Jansen VISS RC3 system with a fire protection requirement of EI60 and equipped with heat-insulated JanisolC4 RC3 fire-proof doors. The VISS façades on the [...] some places triple-curved – mirror panels, MVRDV Architekten opted for the Jansen VISS SG Façade system solution with the RC4 requirements. The 1664 mirrors, which were arranged in 26 rows of 64 mirrors [...] the building in a VISS SG RC4 façade. What’s more, the seamlessly integrated automatic sliding doors in the entrance areas are a special solution that is based on a Jansen steel profile system. All of
athletics infrastructure on a total of eight floors. Fire protection plays a vital role; Janisol 2 EI30 and JanisolC4 EI60 came into use. Lüscher Architekten AG , Zurich/ CH Axess Architekten AG , Zug/ CH
50/60 (E) Janisol 2 (EI) JanisolC4 (EI) VISS fire facades (E / EI) Construction and use of the latest fire protection glazing Fittings requirements Practical workshop instruction Jointing techniques in [...] standards and Jansen steel fire protection construction. Content Current standards and guidelines Instruction in how to use the latest ordering and processing documentation for the systems: Jansen-Economy 50/60 [...] Registration Seminar overview Seminar programme 2018 Die Teilnahme am Jansen Partnerworkshop ist kostenlos Training Department The Jansen Training Department and speciality field managers will be pleased to
building a sense of spaciousness. The strict security standards were met using the VISS Fire and JanisolC4 systems. Read more in the online magazine SCALE Ayala , Madrid/ES Inasus , Lalin/ES Proinller
band with staggered opening ventilation sashes. The Janisol steel profile system in the form of the Janisol HI window elements used as well as Janisol 2 EI30 fire protection sliding doors cover the requirements [...] with staggered ventilation sashes for opening. With this in mind, the Janisol steel profile system – seen here in the form of the Janisol HI window elements – meets the special requirements of the building [...] envelope of a research building. Boltshauser Architekten , Zurich/CH Aepli Metallbau AG , Gossau/CH JanisolC4 fire dampers CH-Zurich
well-known Jansen Economy profiles class E30/EW30/E60/EW60 fire doors and fixed lights up to class E90 can be fitted. The appearance of the Jansen Economy doors is identical with that of the Janisol 2 and Janisol [...] JanisolC4 fire safety systems. The profiles of the 60 depth have very narrow face widths. Jansen Economy profiles allow smoke protection system components with cost-effective flush smoke protection doors [...] combined or only with smoke protection ( Smoke control doors Jansen Economy 60 RS ). Also possible without fire protection, see link for details ( Jansen Economy 60 door ). Test certificates Fire resistance class
(E) Janisol 2 (EI) JanisolC4 (EI) VISS fire facades (E / EI) Construction use of fire protection glazing Fittings requirements Practical workshop instruction Jointing techniques in unit construction Sawing [...] authorised to process Jansen fire protection constructions. Content Standards and guidelines Instruction in how to use the latest ordering and processing documentation for the systems: Jansen-Economy 50/60 (E) [...] Registration Seminar overview Seminar programme 2018 Die Teilnahme am Jansen Partnerworkshop ist kostenlos Training Department The Jansen Training Department and speciality field managers will be pleased to
environmentally compatible sustainable building. The assembly and manufacture of Janisol Primo and combination with Janisol systems are simplified by the use of identical profile cross sections. Materials [...] 14351-1 Tightness against heavy rain up to class 8A Air permeability up to class 4 Resistance to wind load up to class C4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal transmittance Uw
glazed inner façades have been installed in the Jansen VISS RC3 system with a fire protection requirement of EI60 and equipped with heat-insulated JanisolC4 RC3 fire-proof doors. The VISS façades on the [...] some places triple-curved – mirror panels, MVRDV Architekten opted for the Jansen VISS SG Façade system solution with the RC4 requirements. The 1664 mirrors, which were arranged in 26 rows of 64 mirrors [...] the building in a VISS SG RC4 façade. What’s more, the seamlessly integrated automatic sliding doors in the entrance areas are a special solution that is based on a Jansen steel profile system. All of
14351-1 Tightness against heavy rain up to class 9A Air permeability up to class 4 Resistance to wind load up to class C4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal transmittance Uw [...] The slender profile face widths of the Janisol windows made of steel or stainless steel provide space for creativity and lend the building a quite special character. Whether it is sash bar variants, arched [...] arched windows or large-element glazing: the Janisol window system is particularly suitable for use in new buildings as well as for the refurbishment of existing buildings. Materials/surface finishes Uncoated
door profiles in the proven fire protection system Janisol 2 EI30 have been expanded with the installation depth 70 mm. In this way transparent JanisolC4 EI60 fire-resistant partitions - in the extreme case [...] case even EI90 fire-resistant partitions- can be combined with Janisol 2 EI30 without problems. Material / surface finish Uncoated or strip-galvanised steel, suitable for powder coating or stove-enamelling
structural values and achieves top values in system tests (air/water/wind/mechanics). With Janisol HI, Jansen sets new benchmarks in terms of contemporary architecture combined with excellent thermal [...] 14351-1 Tightness against heavy rain up to class 9A Air permeability up to class 4 (600 Pa) Resistance to wind load up to class C4 (1600 Pa) Airborne sound insulation up to Rw 45 db Coefficient of thermal t [...] (1'000'000) Mechanical strength in accordance with EN 1192 class 4 Prefabricated glazing suitable for safety barrier loading DIN 18008-4 met Emergency exit door in accordance with EN 1125 / EN 179 Burglar
standards Fire resistance E45/EW45 Wind load resistance C4 (1600 Pa) Tightness against heavy rain of up to class 8A (450 Pa) Air permeability to class 4 (600 Pa) Load capacity of safety equipment fulfilled [...] Full fire safety range The Janisol 1 system for windows and fixed glazing as well as the systems for doors and fixed glazing round off the fire safety product range. The system meets fire resistance class [...] installation depth or 60 mm (window frame) or 64 mm (window casement) and has the same face as the Janisol window. It also impresses thanks to its simple and efficient processing. Field Renovation and new
set as CONNEX cito Test certificates Resistance to wind load class C4 Tightness against heavy rain class E1050 Air permeability class 4 Uw 1.2 W/m²K - 1.35 W/m²K Burglar resistance in accordance with EN [...] With Connex legno, Jansen offers a window system made of wood, the classic and ecological material, that fulfils today's exacting demands. The wooden contours are identical to those of CONNEX cito, which
Tightness against heavy rain up to class E750 Air permeability up to class 4 (600 Pa) Resistance to wind load up to class C4 (1600 Pa) Airborne sound insulation up to Rw 46 dB Heat transmission coefficient [...] Janisol HI windows combine aesthetics with refined technology. Slender frame profiles enhance the architectural styling while the innovative technology ensures the best possible thermal separation. With [...] EN 1627 to 1630 for RC1N to RC3 Prefabricated glazing suitable for safety barrier loading DIN 18008-4 met RWA / NRWG
the usual way, as with the Janisol and Janisol Arte 2.0 steel profiles – this ensures a high level of process reliability. Benefits Modern opening type Compatible with Janisol Arte 2.0 Concealed fitting [...] capacity of safety devices met Mechanical strength class 4 Impact resistance class 4 Prefabricated glazing suitable for safety barrier loading DIN 18008-4 met [...] Slim tilt and turn windows made from steel profiles With Janisol Arte 66, Jansen is expanding its range of systems to include an attractive variation. The basic depth of 66 mm enables the use of stronger
widths. The appearance is identical to that of the other fire protection systems Economy 60, Janisol 2 and JanisolC4. Materials / surface Uncoated or strip-galvanised steel, suitable for powder coating or [...] protection combined or only with smoke protection ( Smoke control doors Jansen Economy 50 RS ). Also possible without fire protection ( Jansen Economy 50 door ). Test certificates Fire resistance class E30/E [...] control in accordance with DIN 18095 Smoke control tested in accordance with EN 1634-3 Durability (C5) tested in accordance with EN 1191 Emergency exit door in accordance with EN 1125 / EN 179
PE 100 RC Pipe type JANSEN powerwave Wellrohr 63 x 2.9 mm Coefficient of thermal transmittance k2, corrugated pipe ~30 W/mK Minimum bending radius 0.45 m @ 20° C Pressure rating PN 7.4 Safety factor 1.25 [...] 25 Burst pressure 24.1 bar @ 20° C Buckling pressure 6 bar @ 20° C Volume per probe meter 4.54 l/m Special base diameter Ø 130 mm [...] Maximum performance: in comparison to conventional ground source heat loops, the JANSEN powerwave single-u has measurably higher thermal transfer performance and a larger energy storage volume. The structured
product standard EN 14351-1 Tightness against heavy rain up to class 4A Air permeability up to class 4 Resistance to wind load up to class C4/B4 Airborne sound insulation up to Rw 45 dB Coefficient of thermal [...] centres and the like. Stainless steel adds a graceful look and reduces maintenance to a minimum. Janisol stainless steel is therefore the right choice for shopping malls, railway stations, banks and hotels [...] a few additional parts are required, which also remain invisible. The elegant appearance of the Janisol door remains eye-catching. Materials/surface finishes Uncoated or strip-galvanised steel, suitable
14351-1 Tightness against heavy rain up to class 6A Air permeability up to class 4 Resistance to wind load up to class C2/B2 Airborne sound insulation up to Rw 39 dB Shear bonding in accordance with EN [...] The Janisol lift-and-slide door programme re-defines the living room. The proven system, which has been re-developed for large openings, allows the indoors and the outdoors to merge and in this way creates [...] disable access threshold and, on the other hand, also guarantees optimal thermal insulation. The Janisol lift-and slide doors are CE-compliant and have been tested at ift Rosenheim. Materials / surface
The Janisol folding partition is based on the thermally insulated Janisol system and is flexible in use. It can be used as a room divider or for the exterior. The proven system – newly developed for flexible [...] Tightness against heavy rain up to class 8A (450 Pa) Air permeability up to class 4 Resistance to wind load up to class C3/B3 Operating forces class 1 Airborne sound insulation up to Rw 45 dB
dimension 50 mm 1000 mm @ 20° C 1750 mm @ 10° C 2500 mm @ 0° C Pressure ratings PN10, PN16, PN20, PN25, PN30 Safety factor 1.25 Volume per tube meter 5.23 l/m 4.73 l/m 4.12 l/m Approvals / certifications [...] Length Filling volume per m heat loop JANSEN vertex Single-U 50 x 4.6 mm; PN 16 250 to 300 m 5.231 l/m JANSEN vertex Doppel-U 50 x 5.6 mm; PN 20 250 to 350 m 4.73 l/m JANSEN vertex Doppel-U 50 x 7.9 mm PN 30 [...] ground. The JANSEN vertex ground source heat loop is particularly suitable for hot water preparation and for heating and cooling buildings. With the vertex special ground source heat loop, Jansen offers a
up to Class 4 Impact resistance in accordance with EN 13049 up to Class 4 Durability in accordance with EN 12400 Class 7 (500,000) Prefabricated barrier glazing in accordance with DIN 18008-4 [...] Tightness against heavy rain up to Class 8A (450 Pa) Air permeability up to Class 4 (600 Pa) Resistance to wind load up to Class C5/B5 (2000 Pa) Airborne sound insulation up to Rw 45 db Heat transmission coefficient [...] various lock versions, a wide range of materials – namely steel, stainless steel and Corten steel). Janisol Arte 2.0 doors are therefore the right choice for renovations to existing buildings and modern structures
-20° C to +40° C Rec. minimum laying temp. -10° C Dimensions Dimension Pressure rating Capacity per metre pipe 32 x 2.9 mm PN 16 0.517 l 40 x 3.7 mm PN 16 0.802 l 40 x 4.1 mm PN 18 0.762 l 40 x 4.5 mm [...] is expensive; with the JANSEN shark ground source heat systems, filling is also around 4 % less expensive than with conventional smooth pipes. Ground source heat loops With JANSEN shark technology, ground [...] mechanics, Jansen has increased the efficiency of ground source heat systems to a new level. In co-operation with the Institute for Energy Technology at the University of Rapperswil "IET/HSR", Jansen has developed
CH-9463 Oberriet | jansen.com
info@jansen.com | ✆ +41 71 763 91 11
1 Kunststoff / plastics
2 Zentralmagazin / main warehouse
Eichaustrasse 7b
3 Halle / hall J
Eichaustrasse 7c4 Bandstahl / coils
Halle [...] e
P4
im Kessler
Bahnhofstrasse
40m
34m
1
2
3
4
P2
P1
Z
o
ll
am
t
O
b
er
ri
et
Tr
an
si
t
cu
st
o
m
o
f�
ce
Spedition Kunststoff
Logistics plastics
Autobahn/Motorway
4
Jansen [...] S
t.
G
al
le
n
–
C
h
u
r
(A
1
3
)
G
HP
C
B
A
R
Q
E
D
F
J
M
K
L
T
A14
A12
A15
B
ah
n
h
o
f/
st
at
io
n
A
lt
st
ät
te
n
B
uc
h
s
In
d
u
st
ri
es
tr
as
se
St
available are the Jansen Art'15 door system and the Jansen Art'System window system. Janisol Arte 2.0 door Doors made of steel, stainless steel and Corten steel with narrow face widths Janisol Arte 2.0 window [...] insulation up to 45 dB Air permeability Class 4 Tightness against heavy rain 8A Wind load resistance Class C3/B3A3 Durability Class 7 Impact resistance Class 4 Operating forces Class 2 CE label yes BIM model [...] Janisol Arte 2.0 door Extremely slim face widths and outstanding performance values are the hallmarks of the Janisol Arte 2.0 thermally separated steel system, which has previously been used to manufacture
strength class 4 Dangerous substances in accordance with ISO 16000 met Durability class 4 (50,000 cycles) Impact resistance class 4 Prefabricated glazing suitable for safety barrier loading DIN 18008-4 met Burglar [...] 14351-1 Resistance to wind load C5 (2000 Pa) Watertightness up to class 9A (600 Pa) Sound reduction up to 45 dB Thermal transmittance of Uf from 1.9 W/m2K Air permeability class 4 (600 Pa) Load-bearing capacity [...] steel window system for matching the existing style in refurbishments The second generation of the Janisol Arte window system now offers profiles made from stainless steel and Corten steel as well as a wide
to class 4A Air permeability up to class 4 Resistance to wind load up to class C5 Sound insulation up to 44 dB Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance FB 4-6 S/NS [...] door Also available with fire protection ( Fire protection doors Jansen-Economy 60 ) or smoke protection ( Smoke control doors Jansen-Economy 60 RS ). Test certificates CE marking in accordance with product [...] Thanks to its greater installation depth and wall thickness, the Jansen-Economy 60 system is particularly suitable for large, heavy duty single and double doors and for applications requiring higher levels
14351-1 Tightness against heavy rain up to class E900 Air permeability up to class 4 Resistance to wind load up to class C4/B4 Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance [...] With an installation depth of only 50 mm, the Jansen Economy 50 profile system is suitable for slender, elegant window designs without thermal insulation. Tested systemised fittings are available for all
base ø Minimum bending radii at 20° C 32 x 2.9 mm SDR11 / S5 PN 16 60 - 170 m 101 mm 0.65 m 40 x 3.7 mm SDR11 / S5 PN 16 100 - 300 m 115 mm 0.80 m 40 x 4.5 mm SDR9 / S4 PN 20 200 - 325 m 115 mm 0.80 m Range [...] The new generation of ground source heat loops As standard, JANSEN geotwin ground source heat loops are manufactured from notch-resistant, high-quality PE 100 RC material of the latest generation with [...] traceability from the raw material used to the site. The unique, patented double-pipe winding gives the JANSEN geotwin its name and offers various advantages such as: Quick, straightforward reel mounting Even