class RE1200 Air permeability class AE Resistance to wind load class 2 kN/m2 Impact resistance class E5/I5 Burglar resistance RC 2 to 3 Bullet resistance FB4/NS Clamp connection AbZ Z-14.4-459 Mullion-transom [...] doors can be fitted Special technical features Face width 50 and 60 mm Thickness of infill elements, 6 to 70 mm Construction depths 50 to 280 mm Test certificates CE marking in accordance with product standard
class RE1200 Air permeability class AE Resistance to wind load class 2 kN/m2 Impact resistance class E5/I5 TRAV Burglar resistance RC2/3/4 [...] mm Depth of construction to meet structural engineering requirements Thickness of infill elements, 6 to 70 mm Test certificates CE marking in accordance with EN 13830 Coefficient of thermal transmittance
large-format folding doors into end-to-end glass façades (door height of up to 6 metres) and mullion-transom structures (door height of 5 metres). Wind loads, impermeability to driving rain and air permeability
Docu Center"; or has not used the "Jansen Docu Center" for an extended period of time, as a rule for 6 months. 4 Intellectual property and usage rights 4.1 Intellectual property All intellectual property [...] and there shall be no entitlement to the provision of the source code, unless agreed upon in writing. 5 Duties of the User Each User shall have the following duties: To use the "Jansen Docu Center" and its [...] that infringes third party rights or that is relevant under competition, anti-trust or criminal law. 6 Updating of the "Jansen Docu Center" Jansen endeavours to tailor the "Jansen Docu Center" to Users'
pivot doors on the fronts of the buildings with gabled roofs are prominent features of the Rancho 6 complex. When closed, the pivot doors have the appearance of a glass wall surrounded by streamlined [...] pivot doors presented the metalworkers with major challenges: Each panel is five meters tall and 2.5 meters wide, which means each panel weighs around one tonne. The VISS facade system was used to ensure
20 mm 16 x 2.0 20 x 2.0 26 x3.0 32 x 3.0 40 x 3.5 50 x 4.0 63 x 6.0 Kl 1-5 10 bar Kl 1-5 10 bar Kl 1-5 10 bar Kl 1-5 8 bar Kl 1-5 8 bar Kl 1-5 10 bar Kl 1-5 10 bar
0 Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/4 bar Kl 5/4 bar Kl 4/8 bar Kl 5/6 bar Kl 4/8 bar Kl 5/6 bar Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl 4/6 bar Kl 5/4 bar Kl [...] Kl 4/6 bar Kl 5/4 bar
0 14.5 x 1.8 15 x 1.5 15 x 2.5 16 x 2.0 17 x 2.0 18 x 2.0 20 x 2.0 KI 4/10 bar KI 5/8 bar KI 4/10 bar KI 5/8 bar KI 4/5 10 bar KI 4/5 10 bar KI 4/5 10 bar KI 4/8 bar KI 5/6 bar KI 4/5 10 bar KI 4/5 10 bar [...] bar KI 4/5 10 bar KI 4/5 10 bar KI 4/10 bar KI 5/8 bar
and can then be folded outwards. 5. Horizontal pivot window With a horizontal pivot window, the sash rotates on its own axis when opened, with a horizontal axle bearing. 6. Sliding windows / lift-and-slide [...] Depending on the type of arrangement, a distinction is made between different schemes (A, B, C etc.). 5. Folding sliding doors Folding sliding doors generally run along rails and can result in very large [...] larger the openings that can be created. However, ease of movement and safety have to be guaranteed. 6. Anti-finger-trap doors Anti-finger-trap doors offer no alternative opening variant other than the one
below :
Profile holder with pan-head screw ST 5.5x45
Profile holder with pan-head screw ST 5.5x67
Profile holder pre-prepared with pan-head screw ST 5.5
CE classification test
(Since 2022 R3 SP03) [...] below :
Profile holder with pan-head screw ST 5.5x45
Profile holder with pan-head screw ST 5.5x67
Profile holder pre-prepared with pan-head screw ST 5.5
CE classification test
(Since [...] 38
6.5.1 Schüco Integralmaster solar shading: Use in Schüco FWS 60 - Maximum widths
changed 38
6.5.2 Schüco solar shading AB ZDS in Schüco window systems AWS .............................. 38
6.5.3
supply new construction materials; this cable car ran from Muggio for 2.5 km to Monte Generoso. It was able to transport loads of up to 6 t. In each direction there were 3000 journeys that transported more
class 4 Resistance to wind load up to class C5 Sound insulation up to 44 dB Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance FB 4-6 S/NS Emergency exit door in accordance with
fittings Integrated or surface-mounted electric drives Special technical features Installation depth 50/58.5 mm Special geometries (semi-circular tops, trapezoidal windows etc.) Weight of casement up to 180 kg [...] up to class C4/B4 Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance FB6 S/NS
class 5A Air permeability up to class 4 Resistance to wind load up to class C5 Sound insulation up to Rw 45 dB Emergency exit door in accordance with EN 1125 / EN 179 Bullet resistance up to FB6/NS Mechanical
to Rw 45 dB Coefficient of thermal transmittance Uw > 1.5 W/m 2 K Mechanical strength class 4 Operating forces class 1 Impact resistance class 5 Load-bearing capacity of safety devices met Shear bonding [...] EN 14024 Burglar resistance in accordance with EN 1627 up to RC (WK) 3 Bullet resistance FB4 up to FB6 TRAV RWA / NRWG
85 mm Face width, leaf with frame 113.5 mm Test certificates CE marking in accordance with product standard EN 14351-1 Tightness against heavy rain up to class 6A Air permeability up to class 4 Resistance
suitable for powder coating or stove-enamelling Element types Manual folding-sliding glass doors 2 to 6 leaves Inward- and outward-opening Any leaf arrangement Equipment Fittings up to 200 kg Weight of leaf [...] Infill elements, 13 - 37 mm Face width from window overlap area 105 mm Face width, leaf with frame 82.5 mm Test certificates CE marking in accordance with product standard EN 14351-1 Tightness against heavy
nce UD > 1.5 W/m2K Shear bonding in accordance with EN 14024 Durability in accordance with EN 12400 class 8 Burglar resistance in accordance with EN 1627 up to RC3 Bullet resistance FB 4-6 TRAV Emergency
Length Filling volume per m heat loop JANSEN vertex Single-U 50 x 4.6 mm; PN 16 250 to 300 m 5.231 l/m JANSEN vertex Doppel-U 50 x 5.6 mm; PN 20 250 to 350 m 4.73 l/m JANSEN vertex Doppel-U 50 x 7.9 mm [...] 10° C 2500 mm @ 0° C Pressure ratings PN16, PN20, PN25, PN30 Safety factor 1.25 Volume per tube meter 5.23 l/m 4.73 l/m 4.12 l/m Approvals / certifications SKZ Guideline HR 3.26 EN 10204-3.1 Material as per
l 40 x 3.7 mm PN 16 0.802 l 40 x 4.1 mm PN 18 0.762 l 40 x 4.5 mm PN 20 0.725 l 50 x 4.6 mm PN 16 1.255 l 50 x 5.6 mm PN 20 1.135 l 50 x 6.9 mm PN 25 0.988 l 50 x 7.9 mm PN 30 0.881 l The modified inner
the poor thermal properties of these soils. Available options 1 pipe at a depth of 1.5 m 2 pipes at a depth of 1.5 m 4 pipes at a depth of up to 2 m Special versions possible Approvals / certifications [...] are certified in accordance with the latest quality standards and meet the requirements of SIA 384/6, ÖWAV rule sheet 207 and VDI 4640. JANSEN powerwave collect design tool External diameter 63 mm Wall
-20° C … +40°C (DIN 8074) Hydrostatic load class p0 Load capacity of lid A15 (1.5 t) Production according to SIA 384/6, ÖWAV Regelblatt 207, VDI 4640, etc. DVS 2212-1, REACH Robust und functional Made
interlocking connections Qplus certification is extraction-proof up to 250 kg Sealed up to 2.5 bar Angular deflection up to 5° Push-on buffer seal Dimensions Clamping range mm Width mm Reduction mm Weight 100 102 [...] - 194 130 38 1.2 kg 200 183 - 237 130 54 1.8 kg 250 218 - 261 150 43 2.8 kg 300 270 - 324 150 54 4.6 kg 400 345 - 415 190 70 7.2 kg Enormous clamping ranges The three-part swivel joint coupling, made up
Manufactured length 200 mm 6.2 mm 187.6 mm 6 and 10 m 250 mm 7.7 mm 234.6 mm 6 and 10 m 315 mm 9.7 mm 295.6 mm 6 and 10 m 355 mm 10.9 mm 333.2 mm 6 and 10 m 400 mm 12.3 mm 375.4 mm 6 and 10 m [...] mm/mK Serie 12.5 / SDR 26, SN4 Dimension dn Wall thickness en Internal diameter di Manufactured length 110 mm 4.2 mm 101.6 mm 6 and 10 m 125 mm 4.8 mm 115.4 mm 6 and 10 m 160 mm 6.2 mm 147.6 mm 6 and 10 m Serie [...] pipes Double-walled pipes Insulated pipes External diameter dn 110 to 400 mm Length Standard lengths 6 and 10 m Non-standard lengths on request Available options With integrally formed expansion coupling
ÜZ Mainfranken received the award for its "ÜZ – adding value to renewable energy" project. More than 6,350 system s are connected to the grid operated by the energy cooperative, which produces its electricity [...] energy requirement per plot is around 15,000 kWh, which equates to a heat output of approximately 7.5 kW. This required a total of 117 ground source heat loops in boreholes to depths of 30–40 m. 35 plots [...] powerwave single-u ground source heat loops used in Sommerach have a large storage volume of over 4.5 litres per metre of loop. More energy can be stored temporarily in this large volume of brine. This
Commissioning represents the technical release. 16.5.4 The transfer of risk and ownership takes place at the time of commissioning. 16.6 Training 16.6.1 Training on the equipment is carried out at the Jansen [...] delayed delivery or performance; to demand a contractual penalty of 0.5% of the net order value per week or part thereof, up to a maximum of 5% of the net order value. Payment of the contractual penalty shall [...] from the Supplier within 3 months of the first instruction (also at the Jansen AG premises). 5 Acceptance 5.1 Jansen AG is not obliged to accept deliveries that do not correspond to the order in terms
(minimum CHF 50) handling costs per item. Outbound and return freight charges shall not be reimbursed. 5. General Liability Jansen AG is liable within the scope of the mandatory provisions of product liability [...] case, liability for indirect damage / consequential damage incl. financial loss is fully excluded. 6. Delivery and Default The delivery period shall commence on the date of the definitive and complete [...] delivery, the delivery period shall start to run again. Jansen AG shall not be liable for accidents. 6.1 In the event of Force Majeure For the purposes of these GTC, force majeure shall include any and all
of services and contract processing 3. Contacting Jansen 4. Purposes of data processing 5. Duration of storage 6. Your privacy rights 7. Forwarding of data 8. Data processing abroad by contracted third [...] 4.5. Legal basis We process personal data in accordance with Swiss data protection legislation. If and insofar as the EU GDPR is applicable, we also process personal data in accordance with Art. 6 (1) [...] their consent, the legal basis for the processing is Art. 6 (1) lit. a GDPR. Otherwise, the legal basis for the use of LinkedIn Analytics is Art. 6 para. 1 sentence 1 lit. f GDPR. YouTube Features provided
(VISS TVS düşey ve eğimli, Janisol 2 EI30, katlanır kapı)
5STEEL SYSTEMS PROFIL SISTEMLERI
IGuzzini Illuminazione, Barselona/İspanya
(VISS TVS)
6 STEEL SYSTEMS PROFIL SISTEMLERI
Özgün olanaklara
imkan [...] 1200
• Hava geçirgenlik sınıfı AE
• Rüzgar yüküne direnç sınıfı 2 kN/m2
• Darbe direnç sınıfı E5/I5
• DIN 18008-4 kategorisi A ve C2'ye düşmeye korumalı camlar ile
• Passivhauszertifikat
Sadelik [...] bileşen ilavesi ile geniş bir seçenek çeşidi sağlar. Cam
kalınlığı 30 mm ile 70 mm arasındadır. 2.5 mt x 5.0 mt